Viral encephalitis in children: detection with technetium-99m HMPAO brain single-photon emission CT and its value in prediction of outcome.
نویسندگان
چکیده
PURPOSE To assess the role of regional cerebral blood flow measured by technetium-99m hexamethyl propyleneamine oxime (HMPAO) brain single-photon emission CT (SPECT) in viral encephalitis of children. METHODS Eighteen children diagnosed as having viral encephalitis (12 Epstein-Barr virus, 4 herpes simplex virus, and 2 Japanese B virus) underwent Tc-99m HMPAO brain SPECT and brain MR and/or CT. RESULTS During the acute episode, 4 (22%) of the 18 patients had localized abnormality on brain MR and/or CT. Tc-99m HMPAO brain SPECT in the acute phase showed that 17 (94%) of the 18 patients had increased regional cerebral blood flow and 1 (6%) of the 18 children had a normal brain SPECT. Follow-up brain SPECT was performed at least 15 days after the acute episode. In 17 patients with abnormal first brain SPECT, 12 (71%) had normal second brain SPECT and 5 (29%) had decreased regional cerebral blood flow. The group of patients with normal regional cerebral blood flow on the follow-up brain SPECT had a better outcome than the group of patients with decreased regional cerebral blood flow. CONCLUSIONS (a) The Tc-99m HMPAO brain SPECT was abnormal more often than CT or MR in children with acute viral encephalitis and provided better location. (b) In acute episodes of encephalitis, most patients showed locally increased regional cerebral blood flow. (c) After acute episodes, the regional cerebral blood flow returned to normal in most cases. (d) A normal Tc-99m HMPAO brain SPECT in the subacute phase usually indicates a good clinical outcome (no neurologic defect) 1 year after the acute illness in children with viral encephalitis.
منابع مشابه
Single-photon emission CT findings in acute Japanese encephalitis.
PURPOSE To determine the usefulness of single-photon emission CT (SPECT) in the diagnosis of acute Japanese encephalitis (JE). METHODS We examined 10 patients (six men and four women; mean age, 69 years) with viral encephalitis. We divided the cases into two groups: the JE group (n = 4) and the non-JE group (n = 6; two with herpes simplex encephalitis and four with encephalitis of unknown ori...
متن کاملAssessment of regional cerebral blood flow (rCBF) in ischemic stroke using Tc-99m HMPAO SPECT--comparison with CT and MR findings.
To assess the regional cerebral blood flow (rCBF) in ischemic stroke, we analyzed the findings of single photon emission computed tomography (SPECT) using technetium-99m hexamethyl propyleneamine oxime (Tc-99m HMPAO). The SPECT images revealed abnormal areas of decreased perfusion in 29 out of 31 subjects (93.5%), which represented a higher detection rate than those for CT and MR (89.5%, respec...
متن کاملIncreased uptake of technetium-99m-hexamethylpropyleneamine oxime related to primary leptomeningeal melanoma.
We present an autopsy case of primary leptomeningeal melanoma visualized with technetium-99m-hexamethylpropyleneamine oxime (Tc-99m-HMPAO) single photon emission CT (SPECT) of the brain. Increased uptake of Tc-99m-HMPAO coincided with leptomeningeal enhancement on MR images and with the tumor location of the autopsy findings. It was thought that Tc-99m-HMPAO could correlate closely with melanom...
متن کاملBrain FDG-PET Scan and Brain Perfusion SPECT in the Diagnosis of Neuroacanthocytosis Syndromes
Neuroacanthocytosis syndromes (NA) include autosomal recessive chorea-acanthocytosis and X-linked McLeod syndrome consisting of a choreatic movement disorder, psychiatric manifestations and cognitive decline, and additional multi-system features including myopathy and axonal neuropathy. Fluor 18 -2-fluoro-2-deoxyglucose (18F-FDG-PET) positron emission tomography (PET) and technetium 99m -d, l-h...
متن کاملShort reports Serial perfusion brain tomographic scans detect reversible focal ischaemia in Rasmussen’s encephalitis
A 39-year-old man with advanced adultonset Rasmussen’s encephalitis was treated with prednisolone and long-term, high-dose, human intravenous immunoglobulin. A pretreatment, semiquantitative interictal brain perfusion single photon emission computed tomography (SPECT) scan using Tc HMPAO (hexamethylene propylene amine oxime) showed hypoperfusion in the clinically aVected right frontal, parietal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 15 7 شماره
صفحات -
تاریخ انتشار 1994