Cricoid pressure prevents placement of the laryngeal tube and laryngeal tube-suction II.

نویسندگان

  • T Asai
  • R W L Goy
  • E H C Liu
چکیده

BACKGROUND The laryngeal tube has a potential role in patients with a difficult airway, but cricoid pressure is required if the patient is at risk of aspiration. The effect of cricoid pressure on insertion of these devices is unknown. METHODS In a randomized cross-over study, the laryngeal tube (25 patients) or the laryngeal tube-suction II (15 patients) was inserted with cricoid pressure applied on one occasion and with sham pressure on the other occasion. Adequacy of ventilation, time to achieve adequate ventilation, and the leak pressure were assessed. RESULTS Ventilation was adequate in all patients when sham pressure was applied. Cricoid pressure significantly reduced the rate of adequate ventilation to 6 of 25 patients for the laryngeal tube [P < 0.001; 95% confidence interval (CI) for difference: 59-93%] and to 5 of 15 patients for the laryngeal tube-suction II (P < 0.05; 95% CI for difference: 43-91%). The median time taken to achieve adequate ventilation for the laryngeal tube was 10 s [inter-quartile range (IQR): 8-15] (range 5-26) for sham pressure and 25 s (15-32) (15-33) for cricoid pressure; the median leak pressure was 30 (IQR: 30-30) (range 20-30) cm H2O for sham pressure and 15.5 (14.3-20.5) (12-22) cm H2O for cricoid pressure. CONCLUSIONS Continuous cricoid pressure prevents correct placement of the laryngeal tube and the laryngeal tube-suction II such that placement and ventilation via these devices are ineffective. The effect of cricoid pressure on ventilation via these devices, after correct placement, remains unknown.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The laryngeal tube.

The laryngeal tube (VBM Medizintechnik, Sulz, Germany) is a relatively new extraglottic airway, designed to secure a patent airway during either spontaneous breathing or controlled ventilation. In this review article, we have assessed the potential role of the laryngeal tube during anaesthesia and during cardiopulmonary resuscitation. There are four variations of the laryngeal tube: standard la...

متن کامل

DISPOSABLE VERSUS REUSABLE LARYNGEAL TUBE SUCTION FOR VENTILATION IN PATIENTS UNDERGOING LAPAROSCOPIC CHOLECYSTECTOMY Disposable Versus Reusable Laryngeal Tube Suction for Ventilation in Patients Undergoing Laparoscopic Cholecystectomy

The laryngeal tube suction II (LTS-II; VBM, Medizintechnik GmbH, Sulz, Germany) is a recent version of the laryngeal tube (LT) family of supraglottic airway devices originally intended for emergency airway management including out of hospital use 1,2 and unexpected difficult airway situations 3,4, but which are currently also used during general anaesthesia 5-11. The original LT consists of an ...

متن کامل

Laryngeal tube suction for airway management during in-hospital emergencies

OBJECTIVE: The role of supraglottic airway devices in emergency airway management is highlighted in international airway management guidelines. We evaluated the application of the new generation laryngeal tube suction (LTS-II/LTS-D) in the management of in-hospital unexpected difficult airway and cardiopulmonary resuscitation. METHODS: During a seven-year period, patients treated with a laryn...

متن کامل

A randomized controlled trial comparing the ProSeal Laryngeal Mask Airway with the Laryngeal Tube Suction in mechanically ventilated patients.

BACKGROUND The ProSeal Laryngeal Mask Airway (PLMA) (Laryngeal Mask Company, Henley-on-Thames, United Kingdom) is a new laryngeal mask with a modified cuff designed to improve its seal and a drain tube for gastric tube placement. Similarly, the Laryngeal Tube Suction (LTS) (VBM Medizintechnik Gmbh, Sulz a.N, Germany) is a new laryngeal tube that also has an additional channel for gastric tube p...

متن کامل

Comparison of proseal laryngeal mask and endotracheal tube for airway safety in pediatric strabismus surgery.

OBJECTIVE To compare proseal laryngeal mask airway (PLMA) with an endotracheal tube (ET) for airway safety, maintained ease of insertion, and hemodynamic stability in pediatric strabismus surgery (PSS). METHODS This prospective-randomized clinical study was carried out in the Department of Anesthesiology, Faculty of Medicine, Gaziantep University, Turkey between April 2008 and July 2009. Eigh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 99 2  شماره 

صفحات  -

تاریخ انتشار 2007