Comparison of cardiac troponin I immunoassays variably affected by circulating autoantibodies.

نویسندگان

  • Susann Eriksson
  • Tuomo Ilva
  • Charlotte Becker
  • Juha Lund
  • Pekka Porela
  • Kari Pulkki
  • Liisa-Maria Voipio-Pulkki
  • Kim Pettersson
چکیده

BACKGROUND We recently provided evidence that circulating autoantibodies against cardiac troponin I (cTnI) or the troponin complex cause negative interference in cTnI immunoassays. By comparing three cTnI immunoassays, we further explored the phenomenon of circulating autoantibodies and their consequences in patient samples. METHODS We developed a cTnI immunoassay with a novel assay design using three antibodies, two of which bind epitopes outside the stable, central part of cTnI. Samples from 541 chest pain patients were measured with the new cTnI assay and with a first-generation cTnI assay (Innotrac Aio cTnI) using a conventional midfragment assay design. Using another sample cohort, we also compared the new assay with a second-generation cTnI assay (Access AccuTnI). RESULTS The analytical detection limit of the new cTnI assay was 0.012 microg/L, and the lowest concentration giving a total imprecision (CV) of 10% was 0.060 microg/L. The mean difference (95% limits of agreement) between the new cTnI and Aio cTnI assays was larger in admission samples (21.0%; -107.8% to 149.7%) than in samples taken 6-12 h (12.8%; -61.5% to 87.2%) and 24 h after admission (3.0%; -71.3% to 77.4%; P <0.001). With the lowest concentrations giving 10% CV (0.22 microg/L for Aio cTnI) used as cutoffs, 14.3% (n = 76) of admission samples were positive only with the new assay, whereas 13.5% (n = 72) were positive with both assays. Of samples taken at 6-12 and 24 h, 10.2% (n = 31) and 8.3% (n = 29) were positive only with the new assay. ROC curve analysis of admission samples showed a significantly higher area under the curve for the new cTnI assay (0.940) than for the Aio cTnI assay (0.846; P <0.001). The new cTnI assay gave generally lower results than the AccuTnI assay; the mean (95% limits of agreement) differences were -58.9% (-151.8% to 34.0%) in admission samples. In samples with severe interference from autoantibodies, median ratios between the new assay and AccuTnI were higher than in samples with no apparent troponin autoantibodies (0.875 vs 0.481; P<0.001). CONCLUSIONS The new cTnI assay, which is based on a novel antibody combination different from the conventional midfragment antibody approach, offers improved detection of cTnI in samples containing troponin autoantibodies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Negative interference in cardiac troponin I immunoassays by circulating troponin autoantibodies.

BACKGROUND There are numerous potential sources of interference in immunoassays. Our aim was to identify the blood component that causes negative interference in cardiac troponin I (cTnI) immunoassays based on antibodies against the central part of cTnI. METHODS We isolated an interfering factor (IF) from a sample with low recovery of added cTnI, using several consecutive purification steps: ...

متن کامل

Validation of Serum Cardiac Troponin I Reference Materials Using an Immunoprecipitation Method Coupled with Fluorescent Western Blot Analysis

Cardiac troponin I (cTnI) is adopted as the ‘gold standard’ cardiac biomarker following the universal definition of myocardial infarction (MI). Presently, the performance of commercial cTnI immunoassays varies significantly despite the recalibration using a troponin standard reference material, NIST SRM 2921. To standardize the cTnI immunoassays, a secondary reference material consisting of a p...

متن کامل

Epitope specificity and IgG subclass distribution of autoantibodies to cardiac troponin.

BACKGROUND Autoantibodies to cardiac troponins (cTnAAbs) can interfere with the measurement of cardiac troponin I (cTnI) by immunoassays for the diagnosis of myocardial infarction. Therefore, we determined the cTnI binding sites and IgG subclasses of circulating cTnAAbs. METHODS We studied epitope specificity with sandwich-type immunoassays by measuring the recovery of troponin complex added ...

متن کامل

Selection of antibodies and epitopes for cardiac troponin immunoassays: should we revise our evidence-based beliefs?

Cardiac troponins are regarded as the most specific and sensitive of the currently available diagnostic techniques for detection of myocardial damage, and the redefined criteria used to classify acute coronary syndrome patients presenting with ischemic symptoms as myocardial infarction patients are heavily predicated on an increased concentration of these markers in blood (1 ). Troponins also a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 51 5  شماره 

صفحات  -

تاریخ انتشار 2005