Adsorption of hexavalent chromium by polyacrylonitrile-based porous carbon from aqueous solution

نویسندگان

  • Bin Feng
  • Wenzhong Shen
  • Liyi Shi
  • Shijie Qu
چکیده

Owing to the unique microporous structure and high specific surface area, porous carbon could act as a good carrier for functional materials. In this paper, polyacrylonitrile (PAN)-based porous carbon materials (PPC-0.6-600, PPC-0.8-600, PPC-0.6-800 and PPC-0.8-800) were prepared by heating KOH at 600°C and 800oC for the removal of Cr(VI) from aqueous solution. The adsorbent was characterized by the techniques of Fourier transform infrared spectroscopy (FT-IR), elementary analysis, scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and N2 adsorption techniques. The results showed that the adsorption capacity increased with decreasing pH value of the initial solution. The adsorption capacity of Cr(VI) on PPC-0.8-800 was much greater than that on other materials, and maximum adsorption capacity were calculated to be 374.90 mg g-1. Moreover, PPC-0.8-800 had superior recyclability for the removal of Cr(VI) from wastewater, about 82% of its initial adsorption capacity was retained even after five cycles. The result of kinetic simulation showed that the adsorption of Cr(VI) on the PAN-based porous carbon could be described by pseudo-second-order kinetics. The adsorption process was the ionic interaction between protonated amine groups of PPC and HCrO4- ions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Removal of Hexavalent Chromium Using Activated Carbons Derived from Marine Algae Gracilaria and Sargassum Sp

Industrial wastewater contain higher quantities of salts besides chromium (VI) ions, therefore, the effect of these salts on the adsorption of chromium (VI) should be studied. In this research, the batch removal of toxic hexavalent chromium ions from wastewater and aqueous solution using two different activated carbon marine algae Gracilaria (red algae) and Sargassum sp. (brown algae) were exam...

متن کامل

Removal of hexavalent chromium from aqueous solution using canola biomass: Isotherms and kinetics studies

The removing of hexavalent chromium from wastewater or decreasing its chromium (VI) content up to the permitted levels is important due to its non-biodegradation, bioaccumulation, and cancer-causing and toxic effects. In the present study, biosorption of Cr (VI) from aqueous solutions using canola was investigated. The various physicochemical parameters such as pH, initial Cr (VI) ion concentra...

متن کامل

Removal of Hexavalent Chromium Ions from Aqueous Solution by Adsorption Using Activated Carbon Prepared from Cucumis Melo Peel Activated carbon

Activated carbon prepared from Cucumis Melo Peel was used as adsorbent for the removal of chromium ion from aqueous solution. Adsorption experiments were performed by varying initial metal ion concentration, temperature, and pH. Freundlich and Langmuir isotherms were used to analyze the equilibrium data obtained at different adsorption conditions. Adsorption results obtained, shows that the Cr ...

متن کامل

INVESTIGATING SELECTIVE REMOVAL OF Cr(VI) AND Zinc IONS FROM AQUEOUS MEDIA BY MECHANICAL-CHEMICAL ACTIVATED RED MUD

In this study, the adsorption of hexavalent chromium and zinc ions from the solution is investigated by raw red mud and mechanical-chemical activated red mud along with the possibility of selective reclamation of these ions from the solution. The mechanical-chemical activation of red mud was done by employing high-energy milling and subsequent acid treatment with HNO3. Raw red mud (RRM) and mec...

متن کامل

Removal of chromium (VI) from aqueous solution by adsorption using cousinia eryngioides boiss and activated carbon

Adsorption capacity of Cr (VI) onto cousinia eryngioides boiss, activated carbon was investigated in a batch system by considering the effects of various parameters like contact time, initial concentration, pH, temperature, agitation speed, absorbent dose and particle size. Cr (VI) removal is pH dependent and found to be maximum at pH 2.0. The amounts of Cr (VI) adsorbed increased with increase...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2018