Repeatability and Reproducibility of Corneal Biometric Measurements Using the Visante Omni and a Rabbit Experimental Model of Post-Surgical Corneal Ectasia.
نویسندگان
چکیده
PURPOSE To investigate the repeatability and reproducibility of the Visante Omni topography in obtaining topography measurements of rabbit corneas and to develop a post-surgical model of corneal ectasia. METHODS Eight rabbits were used to study the repeatability and reproducibility by assessing the intra- and interobserver bias and limits of agreement. Another nine rabbits underwent different diopters (D) of laser in situ keratosmileusis (LASIK) were used for the development of ectasia model. All eyes were examined with the Visante Omni, and corneal ultrastructure were evaluated with transmission electron microscopy (TEM). RESULTS There was no significant intra- or interobserver difference for mean steep and flat keratometry (K) values of simulated K, anterior, and posterior elevation measurements. Eyes underwent -5 D LASIK had a significant increase in mean amplitude of astigmatism and posterior surface elevation with time (P for trend < 0.05). At 2 and 3 months, the -5 D LASIK group had significant greater mean amplitude of astigmatism (P = 0.036; P = 0.027) and posterior surface elevation (both P < 0.005) compared with control group. On TEM, the mean collagen fibril diameter and interfibril distance in the -5 D LASIK eyes were significantly greater than in controls at 3 months (P = 0.018; P < 0.001). CONCLUSIONS The Visante Omni provided imaging of the rabbit cornea with good repeatability and reproducibility. Application of -5 D LASIK treatment produced a rabbit model of corneal ectasia that was gradual in development and simulated the human condition. TRANSLATIONAL RELEVANCE The results provide the foundations for the future evaluation of novel treatment modalities for post-surgical ectasia and keratoconus.
منابع مشابه
Reliability of RTVue, Visante, and Slit-Lamp Adapted Ultrasonic Pachymetry for Central Corneal Thickness Measurement
PURPOSE To evaluate reliability of Fourier-domain optical coherence tomography (OCT) (RTVue), time-domain OCT (Visante), and slit-lamp adapted ultrasonic pachymetry (SL-US) in the measurement of central corneal thickness (CCT). MATERIALS AND METHODS Thirty healthy volunteers visited our clinic 3 times and fifty eyes were measured by one physician. RTVue and Visante were randomly performed, an...
متن کاملRepeatability and reproducibility of pachymetric mapping with Visante anterior segment-optical coherence tomography.
PURPOSE To determine the repeatability and reproducibility of central and peripheral corneal pachymetry mapping with anterior segment-optical coherence tomography (AS-OCT). METHODS An observational cross-sectional study involving two groups: 27 healthy eyes and 20 eyes with keratoconus. Each subject underwent scanning sessions with AS-OCT to determine intraobserver repeatability, interobserve...
متن کاملEvaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents
Purpose. To assess the repeatability and reproducibility of ocular biometry and intraocular lens (IOL) power measurements obtained by ophthalmology residents using an AL-Scan device, a novel optical biometer. Methods. Two ophthalmology residents were instructed regarding the AL-Scan device. Both performed ocular biometry and IOL power measurements using AL-Scan, three times on each of 128 eyes,...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملComparison of artemis 2 ultrasound and Visante optical coherence tomography corneal thickness profiles.
PURPOSE To compare corneal thickness profiles of cross-sections of cornea determined by arc-scanned immersion ultrasound and optical coherence tomography (OCT). METHODS Corneas of 28 eyes from 14 participants were scanned in triplicate using the Artemis 2 high-frequency arc-scanned ultrasound system (ArcScan Inc) and the Visante OCT system (Carl Zeiss Meditec). Corneal thickness and reproduci...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Translational vision science & technology
دوره 4 2 شماره
صفحات -
تاریخ انتشار 2015