High sensitivity pyrogen testing in water and dialysis solutions.
نویسندگان
چکیده
BACKGROUND The dialysis patient is confronted with hundreds of litres of dialysis solution per week, which pass the natural protective barriers of the body and are brought into contact with the tissue directly in the case of peritoneal dialysis or indirectly in the case of renal dialysis (hemodialysis). The components can be tested for living specimens or dead pyrogenic (fever-inducing) contaminations. The former is usually detected by cultivation and the latter by the endotoxin-specific Limulus Amoebocyte Lysate Assay (LAL). However, the LAL assay does not reflect the response of the human immune system to the wide variety of possible pyrogenic contaminations in dialysis fluids. Furthermore, the test is limited in its sensitivity to detect extremely low concentrations of pyrogens, which in their sum result in chronic pathologies in dialysis patients. The In vitro Pyrogen Test (IPT) employs human whole blood to detect the spectrum of pyrogens to which humans respond by measuring the release of the endogenous fever mediator interleukin-1beta. Spike recovery checks exclude interference. The test has been validated in an international study for pyrogen detection in injectable solutions. METHODS In this study we adapted the IPT to the testing of dialysis solutions. RESULTS Preincubation of 50 ml spiked samples with albumin-coated microspheres enhanced the sensitivity of the assay to detect contaminations down to 0.1 pg/ml LPS or 0.001 EU/ml in water or saline and allowed pyrogen detection in dialysis concentrates or final working solutions. CONCLUSIONS This method offers high sensitivity detection of human-relevant pyrogens in dialysis solutions and components.
منابع مشابه
On-line preparation of solutions for dialysis: practical aspects versus safety and regulations.
On-line preparation, i.e., continuous mixing and immediate use, was introduced for dialysis fluid in 1964, and it contributed significantly to the expansion of dialysis therapy through simplified handling, improved microbiology, and enhanced efficiency. On-line prepared replacement solution for hemofiltration was shown to be clinically safe as early as 1978, but the implementation was delayed f...
متن کاملEndotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen Test
The possibility of replacing the rabbit pyrogen test by the Limulus Amebocyte lysate (LAL) test, as a final release test for Large Volume Parenterals (LVPs) was investigated. The sensitivity and specificity of the LAL test and rabbit pyrogen assay were studied by means of artificially contaminated parenterals. Various LVPs (mostly containing electrolytes) were spiked with 0.5 and 5 EUlml o...
متن کاملLooking beyond endotoxin: a comparative study of pyrogen retention by ultrafilters used for the preparation of sterile dialyis fluid
Sterile single-use ultrafilters are used in dialysis for the preparation of the substitution fluid given to patients undergoing dialysis treatments with high convective fluid removal. The retention of pyrogenic agents by the ultrafilters is crucial to avoiding inflammatory responses. The performance of a new single-use ultrafilter (NUF) with a positively charged flat sheet membrane of relativel...
متن کاملCytotoxic Glucose Degradation Products in Fluids for Peritoneal Dialysis
During the standard heat sterilization process of the lactate–buffered peritoneal dialysis solutions, glucose (an osmotic active substance) degrades to form compounds called glucose degradation products which are cytotoxic and affect the survival of the peritoneal membrane. This case presentation is based on an observation of 224 aseptic peritonitis cases of unknown etiology. For the purpose of...
متن کاملDEVELOPMENT OF A METHOD FOR ALUMINIUM DETERMINATION IN SERUM AND DIALYSIS FLUID BY FLAMELESS ATOMIC ABSORPTION WITH GRAPHITE FURNACE
Aluminium determination was carried out in serum and dialysis fluid by a simple and reliable method of nameless atomic absorption with graphite furnace . . No preparatory procedures are required for water and dialysis fluid. In this method serum was mixed with 0.2% HNO, to allow complete combustion of the samples in order to improve analytical precision. The method has a sensitivity of 15 p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of immunological methods
دوره 336 1 شماره
صفحات -
تاریخ انتشار 2008