Prospective swallowing motion self-gating: a feasibility study in carotid artery wall MRI using 3D variable-flip-angle TSE
نویسندگان
چکیده
Background 3D black-blood MRI is a promising imaging modality for carotid artery wall imaging but is inherently susceptible to motion. Previous work shown that swallowing can result in the greatest motion at the carotid bifurcation and its vicinity (1). A self-gating (SG) method in combination with a 3D variable-flip-angle turbo spinecho sequence, SPACE, has recently been proposed for gating swallowing motion (2). This work aimed to validate the utility of the new technique on healthy volunteers and patients.
منابع مشابه
Prospective Self-Gating To Eliminate Motion Artifacts in 3D Carotid Artery Wall Imaging
Introduction: 3D variable-flip-angle TSE (SPACE) has been proposed for carotid vessel wall imaging [1]. However, a relatively long imaging time renders this technique more prone to image artifacts caused by apparent motion such as swallowing. Self-gating technique [2] has recently been used to exclude data acquired during swallowing, yet two shortcomings remain. First, a single self-gating (SG)...
متن کامل3D SPACE Arterial Wall Imaging with Prospective Self-Gating for Motion Compensation
reformatted images from non-gated and self-gated SPACE imaging. Note that images suffered from severe motion artifacts due to swallowing without self-gating motion compensation. Figure 2. (a) Correlation coefficients calculated between each projection and the reference profile; (b) Self-gating projection signals of the neck as a function of time; (c) Two projection signals acquired with and wit...
متن کامل3D Volume Selective TSE for carotid artery wall imaging with navigator detection of swallowing
L. A. Crowe, J. Keegan, P. Gatehouse, R. Mohiaddin, A. Varghese, K. Symmonds, T. Cannell, G-Z. Yang, D. N. Firmin CMR Unit, Imperial College/Royal Brompton Hospital, London, United Kingdom, VIP Group, Department of Computing, Imperial College, London, United Kingdom Aim Improvement of 3D volume selective TSE carotid artery wall imaging by the addition of navigators to reduce artefacts caused by...
متن کاملComparative Evaluations of 3d Turbo Spin Echo (tse) Motion Sensitized Driven Equilibrium (msde) and 2d Double Inversion Recovery Tse Sequences for T1-weighted Black-blood Carotid Atherosclerosis Imaging
Introduction In vivo MR carotid plaque imaging has been used to identify vessel morphology and plaque characteristics, and their associations with clinical symptoms. [1] Two-dimensional T1 weighted (T1W) double inversion recovery spin echo [2] and subsequently quadruple inversion recovery spin echo sequences [3] have been used to obtain the contrast between vessel wall and lumen, and identify c...
متن کاملThree-dimensional Whole-Heart Cine MRI using Prospective Self-Gating for Compensation of Cardiac and Respiratory Motion
Introduction: Two-dimensional (2D) breath-hold and ECG-triggered cine MRI is frequently used to assess cardiac function. However this technique requires cooperation from the patient, and the MR acquisition has to be synchronized with the cardiac cycle using ECG. To control respiratory motion, the subject has to perform breath-holds or the position of the diaphragm has to be tracked using a resp...