Incorporating seed orientation in brachytherapy implant reconstruction
نویسندگان
چکیده
Intra-operative quality assurance and dosimetry optimization in prostate brachytherapy critically depends on the ability of discerning the locations of implanted seeds. Various methods exist for seed matching and reconstruction from multiple segmented C-arm images. Unfortunately, using three or more images makes the problem NP-hard, i.e. no polynomial-time algorithm can provably compute the complete matching. Typically, a statistical analysis of performance is considered sufficient. Hence it is of utmost importance to exploit all the available information in order to minimize the matching and reconstruction errors. Current algorithms use only the information about seed centers, disregarding the information about the orientations and length of seeds. While the latter has little dosimetric impact, it can positively contribute to improving seed matching rate and 3D implant reconstruction accuracy. It can also become critical information when hidden and spuriously segmented seeds need to be matched, where reliable and generic methods are not yet available. Expecting orientation information to be useful in reconstructing large and dense implants, we have developed a method which incorporates seed orientation information into our previously proposed reconstruction algorithm (MARSHAL). Simulation study shows that under normal segmentation errors, when considering seed orientations, implants of 80 to 140 seeds with the density of 2.03.0 seeds/cc give an average matching rate >97% using three-image matching. It is higher than the matching rate of about 96% when considering only seed positions. This means that the information of seed orientations appears to be a valuable additive to fluoroscopy-based brachytherapy implant reconstruction.
منابع مشابه
Detection and correction of patient movement in prostate brachytherapy seed reconstruction.
Intraoperative dosimetry of prostate brachytherapy can help optimize the dose distribution and potentially improve clinical outcome. Evaluation of dose distribution during the seed implant procedure requires the knowledge of 3D seed coordinates. Fluoroscopy-based seed localization is a viable option. From three x-ray projections obtained at different gantry angles, 3D seed positions can be dete...
متن کاملComparison of two treatment approaches for prostate cancer: intensity‐modulated radiation therapy combined with I125 seed‐implant brachytherapy or I125 seed‐implant brachytherapy alone
The purpose of the present study was to assess the results of two different treatment approaches for clinically localized prostate cancer: intensity-modulated radiation therapy (IMRT) followed by 125I seed-implant brachytherapy and 125I seed-implant brachytherapy alone. We studied our 30 most recent consecutive patients. The sample population consisted of 15 cases treated with IMRT (50.4 Gy) fo...
متن کاملClinical implementation of a digital tomosynthesis-based seed reconstruction algorithm for intraoperative postimplant dose evaluation in low dose rate prostate brachytherapy.
PURPOSE The low dose rate brachytherapy procedure would benefit from an intraoperative postimplant dosimetry verification technique to identify possible suboptimal dose coverage and suggest a potential reimplantation. The main objective of this project is to develop an efficient, operator-free, intraoperative seed detection technique using the imaging modalities available in a low dose rate bra...
متن کاملDynamic Dosimetry and Edema Detection in Prostate Brachytherapy - a Complete System
Purpose: Brachytherapy (radioactive seed insertion) has emerged as one of the most effective treatment options for patients with prostate cancer, with the added benefit of a convenient outpatient procedure. The main limitation in contemporary brachytherapy is faulty seed placement, predominantly due to the presence of intraoperative edema (tissue expansion). Though currently not available, the ...
متن کاملThree-dimensional seed reconstruction for prostate brachytherapy using Hough trajectories.
In order to perform intra-operative or post-implant dosimetry in prostate brachytherapy, the 3D coordinates of the implanted radioactive seeds must be determined. Film or fluoroscopy based seed reconstruction techniques use back projection of x-ray data obtained at two or three x-ray positions. These methods, however, do not perform well when some of the seed images are undetected. To overcome ...
متن کامل