Purpose. To evaluate and compare the accuracy of different intraocular lens (IOL) power calculation formulas for eyes with an axial length (AL) greater than 26.00 mm. Methods. This study reviewed 407 eyes of 219 patients with AL longer than 26.0 mm. The refractive prediction errors of IOL power calculation formulas (SRK/T, Haigis, Holladay, Hoffer Q, and Barrett Universal II) using User Group for Laser Interference Biometry (ULIB) constants were evaluated and compared. Results. One hundred seventy-one eyes were enrolled. The Barrett Universal II formula had the lowest mean absolute error (MAE) and SRK/T and Haigis had similar MAE, and the statistical highest MAE were seen with the Holladay and Hoffer Q formulas. The interquartile range of the Barrett Universal II formula was also the lowest among all the formulas. The Barrett Universal II formulas yielded the highest percentage of eyes within ±1.0 D and ±0.5 D of the target refraction in this study (97.24% and 79.56%, resp.). Conclusions. Barrett Universal II formula produced the lowest predictive error and the least variable predictive error compared with the SRK/T, Haigis, Holladay, and Hoffer Q formulas. For high myopic eyes, the Barrett Universal II formula may be a more suitable choice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular lens power calculation and optimized constants for highly myopic eyes.

PURPOSE To determine the accuracy of intraocular lens (IOL) power calculations in eyes with high myopia and to suggest adjusted constants for these cases. SETTING Centre for Ophthalmology, Eberhard-Karls-University, Tuebingen, Germany. METHODS Patients with high myopia having phacoemulsification with implantation of an AcrySof MA60MA IOL (power range +5.00 to -5.00 diopters [D]) were evalua...

متن کامل

No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis.

PURPOSE To prospectively evaluate the no-history method for intraocular lens (IOL) power calculation in 15 cataractous eyes that had previous myopic laser in situ keratomileusis (LASIK) and for which the pre-LASIK K-readings were not available. SETTING Private practice, Lynwood, California, USA. METHODS The predicted IOL power was calculated in each case. Also calculated were the mean arith...

متن کامل

Efficacy and Safety of Cataract Extraction with Negative Power Intraocular Lens Implantation§

PURPOSE To evaluate the visual and refractive outcomes, lens power calculation accuracy, and safety of negative power intraocular lenses (IOLs) implanted in highly myopic eyes at the time of cataract surgery. DESIGN Interventional case series. METHODS Sixteen consecutive highly myopic eyes implanted with IOLs from -1 D to -6 D were identified. IOL power; preoperative and postoperative best-...

متن کامل

A study regarding efficacy of various intraocular lens power calculation formulas in a subset of Indian myopic population

Efficacy of intraocular lens power calculation formulas in a subset of Indian myopic population. Retrospectively reviewed 43 patients who underwent phacoemulsification with high axial length (AL) (>24.5 mm, range 24.75-32.35 mm). The power of the implanted intraocular lens (IOL) was used to calculate the predicted post-operative refractive error by four formulas: Sanders-Retzlaff-Kraff (SRK II)...

متن کامل

Comparison of intraocular lens power calculation methods in eyes that have undergone laser-assisted in-situ keratomileusis.

PURPOSE To compare methods of calculating intraocular lens (IOL) power for cataract surgery in eyes that have undergone myopic laser-assisted in-situ keratomileusis (LASIK). METHODS Eleven eyes of eight patients who had previously undergone myopic LASIK (amount of LASIK correction, -5.50 +/- 2.61 D (SD); range, -8.78 to -2.38 D) and subsequently phacoemulsification with implantation of the SA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of ophthalmology

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016