Inverse Verification of the Dose Distribution for Intensity Modulated Radiation Therapy Patient-specific Quality Assurance Using Dynamic MLC Log Files
نویسندگان
چکیده
The aim of this study was to investigate a novel method for verification of the dose distribution for intensity modulated radiation therapy (IMRT) patient-specific quality assurance (QA) using dynamic multi-leaf collimator (DMLC) log files (Dynalog files). Dynalog files are recorded every 50 ms by using a MLC controller during the IMRT treatment. Dynalog files contain actual MLC positional information for various delivered dose fractions. As the nonuniform fluence is directly influenced by the MLC positional accuracy, our method for IMRT patient-specific QA can be performed using this information. Three nasopharyngeal cancer patients were selected for the evaluation. We developed an in-house program to convert MLC log files from an MLC controller to delivered MLC (dMLC) field files for the interface between the MLC controller and the treatment planning system. The in-house software, DMLC field file (DFF) converter, was written using programming language (Visual C++ 2005, Microsoft, Redmond, WA, USA). For inverse planning, Eclipse (v. 6.5, Varian, Palo Alto, USA) was used. The MLC log files were converted to dMLC files. The IMRT plans were recalculated and compared with the original plans. Comparisons were done via planar dose distributions using OP-IMRT software (v. 1.4, Wellhofer Dosimetrie, Germany) and dose volume histograms (DVHs) for targets and organs at risk (OARs). Gamma index (dose difference: 3%, distance to agreement: 3 mm) calculations were also performed for a quantitative analysis. There were significant differences (maximum dose difference: 587 cGy, maximum volume difference at 3000 cGy: 17%) in the DVHs of the parotid glands between planned MLC (pMLC)based and delivered MLC (dMLC)-based inverse IMRT QA (IVQA) plans for all three patients. The histograms showed an increased dose-volume in the dMLC-based IVQA deliveries compared to reference (Ref.) IMRT plans. Based on the present study, we can confirm the availability of our new approach to perform IMRT patient-specific QA providing a convenient and clear tool for IMRT dose verification. In the future, this method should be available for inverse on-treatment dose verification and for pre-treatment IMRT QA.
منابع مشابه
The Quality Control of Intensity Modulated Radiation Therapy (IMRT) for ONCOR Siemens Linear Accelerators Using Film Dosimetry
Introduction Intensity Modulated Radiation Therapy (IMRT) has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various ...
متن کاملPlanning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: a strategy for large-scale implementation for the treatment of carcinoma of the prostate.
PURPOSE To improve the local control of patients with adenocarcinoma of the prostate we have implemented intensity modulated radiation therapy (IMRT) to deliver a prescribed dose of 81 Gy. This method is based on inverse planning and the use of dynamic multileaf collimators (DMLC). Because IMRT is a new modality, a major emphasis was on the quality assurance of each component of the process and...
متن کاملValidation of dynamic MLC-controller log files using a two-dimensional diode array.
Intensity-modulated radiation therapy (IMRT) delivered with multi-leaf collimator (MLC) in the step-and-shoot mode uses multiple static MLC segments to achieve intensity modulation. For typical IMRT treatment plans, significant numbers of segments are delivered with monitor units (MUs) of much less than 10. Verification of the ability of the linear accelerator (linac) to deliver small MU segmen...
متن کاملDesign, Simulation and Manufacture of a Multileaf Collimator to Confirm the Target Volumes in Intensity Modulated Radiation Therapy
Introduction: Intensity modulated radiation therapy (IMRT) is one of the cancer treatment methods. It is important to selectively aim at the target in this way, which can be performed using a multileaf collimator (MLC). Materials and Methods: In order to specifically irradiate the target volume in radiotherapy to reduce the patient absorbed dose, the use of multileaf collimator has been investi...
متن کاملThe Dosimetric Effects of Different Multileaf Collimator Widths on Physical Dose Distributions
Introduction: Geometric changes in the multileaf collimator (MLC) led to dosimetric considerations in intensity-modulated radiation therapy (IMRT) due to the number and size of the pixels in the intensity map, which are determined by the MLC leaf width. In this study, we evaluated the dosimetric effects of different MLC widths on physical dose distributions for IMRT plans. Materials and Method...
متن کامل