Unique relationship between osteophyte and femoral-tibia component size mismatch in determining polyethylene wear in primary total knee arthroplasty: a case report

نویسندگان

  • Manjunath Ramappa
  • Andrew Port
چکیده

INTRODUCTION Knee pain is a complex problem that can occur after total knee arthroplasty. One cause of knee pain may be due to a retained osteophyte, but it is not clear if the retained osteophyte is sufficient explanation of the pain, as not all patients with retained osteophytes are symptomatic. In fact, the literature shows that excised osteophytes can also recur over a period of time, without any symptoms. Therefore a retained osteophyte alone is probably not sufficient to cause symptoms. CASE PRESENTATION We present a case of intermittent medial knee pain occurring post-primary total knee arthroplasty, in a patient who underwent several investigations over a period of 5 years. Radiographs showed an osteophyte in the postero-medial femur along with slight tibial component overhang which was normal for that knee implant design. The symptoms eventually settled with excision of only the osteophyte, without altering the tibial component. CONCLUSION A retained osteophyte alone, or tibial component overhang alone, did not seem to cause significant symptoms in our patient whose symptoms completely settled with excision of the osteophyte alone, without changing the tibial component. Therefore, it seems that the combination of retained osteophyte and tibial component overhang (tibia-femoral component size mismatch) are detrimental and therefore best avoided. This report also emphasises the importance of meticulous osteophyte excision and avoiding tibial component overhang during knee arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Post impingement in posterior stabilised total knee arthroplasty.

Posterior stabilised implants are a well-proven treatment for patients requiring primary total knee arthroplasty. Concerns about the posterior stabilised (PS) design have been raised and recent studies suggest that the post-cam articulation can be an additional source of polyethylene wear debris. In this study, the authors report impingement of the tibial post against the patellar component in ...

متن کامل

Posterior Tibial Polyethylene Fracture in Cruciate-Retaining Total Knee Arthroplasty

Introduction One of the common prostheses for primary total knee arthroplasty (TKA) is a cruciate-retaining (CR) design. The tibial polyethylene inserts commonly used in TKA are made of ultra-high molecular weight polyethylene (UHMWPE). The CR TKA design retains the posterior cruciate ligament (PCL), which is believed to provide increased stability, promote femoral roll back, improve propriocep...

متن کامل

Early failure with massive metallosis and posteromedial wear following atraumatic anterior cruciate ligament rupture after medial unicompartmental knee arthroplasty

Severe metallosis following medial unicompartmental knee arthroplasty (UKA) is relatively rare. It is usually due to long-standing wear of the polyethylene component, resulting in frictional wear between the femoral and tibial metallic components. Biomechanical and cadaveric studies have shown the effects of anterior cruciate ligament (ACL) transection following medial UKA. We describe a case o...

متن کامل

Role of abrasion of the femoral component in revision knee arthroplasty.

We carried out 60 revision procedures for failed porous coated anatomic total knee replacements in 54 patients, which were divided into two groups. The 14 knees in group I had a well-fixed femoral component at surgery which was retained, and in the 46 knees in group II both tibial and femoral components were loose and were revised using a variety of implants. Our review comprised clinical and r...

متن کامل

Femoral Component Survival in Hybrid Total Knee Arthroplasty.

Although the majority of North American surgeons perform total knee arthroplasty by cementing both the femoral and the tibial components, hybrid fixation with a press-fit femur and cemented tibia is an alternative form of total knee arthroplasty performed by some. Currently, there is a paucity of literature evaluating long-term outcomes after hybrid total knee arthroplasty. As such, the purpose...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2009