Technical note: measuring portal blood flow in sheep using an ultrasonic transit time flow probe.
نویسندگان
چکیده
Our objective was to validate the use of an ultrasonic transit-time flowmeter for the measurement of portal blood flow (PBF) in sheep. Data recorded with this technique were compared with those obtained with an indicator dilution method, and probes were calibrated in vivo. Wethers were fitted with catheters in the portal, jejunal, and ruminal veins and in a mesenteric artery. Ultrasonic flow probes were implanted around the portal vein: S-series probes in three wethers, and A-series probes in four wethers. The PBF measured with A-series probes was within 10% of that measured by indicator dilution, but PBF measured with S-series probes were 52 to 77% of that determined by indicator dilution. In vivo calibration indicated that A-series probes provided accurate measurement of PBF (absolute accuracy: 5%+/-zero flow error). In conclusion, an ultrasonic transit-time flowmeter, with an A-series probe, can be used to reliably measure PBF in sheep.
منابع مشابه
Technical note: An improved surgical model for the long-term studies of kinetics and quantification of nutrient absorption in swine.
An improved technique to study kinetics and quantitative absorption of nutrients in pigs is described. Three female pigs (35 kg of BW) were surgically modified with catheters in the hepatic portal vein and carotid artery and an ultrasonic flow probe around the portal vein. Catheter placement and patency was secured using distal modifications (rings and holes) and nonabsorbable suture. Catheters...
متن کاملOptimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement
Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...
متن کاملAn Enhanced Technique for Ultrasonic Flow Metering Featuring Very Low Jitter and Offset
This paper proposes a new, improved method for water flow metering. It applies to a transit time ultrasonic flow meter device. In principle, the flow of a given liquid in a pipe is obtained by measuring the transit times of an ultrasonic wave in the upstream and downstream directions. The difference between these times is, in theory, linearly proportional to the liquid flow velocity. However, t...
متن کاملIn Vitro Comparison of ECC Blood Flow Measurement Techniques
-----------------Four extracorporeal blood flow measurement devices were compared for accuracy: the digital display (Stockert-Shiley roller pump), the Sarns doppler flow probe, the Transonic ultrasonic flow probe and the Biomedicus electromagnetic flow probe. The effects of changing temperature and hematocrit at various flows were compared. Eighty-four blood flow measurements were recorded for ...
متن کاملValidation in the sheep of an ultrasound velocity dilution technique for haemodialysis graft flow.
BACKGROUND A simple, rapid, inexpensive method for measuring the flow in a patient's vascular access would permit routine monitoring during haemodialysis, and hence provide information of access graft deterioration sufficiently early to increase the success of minimally invasive remedial procedures. This paper reports the validation of such a method in animals. METHODS A PTFE graft was implan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of animal science
دوره 76 10 شماره
صفحات -
تاریخ انتشار 1998