A label-free electrochemical immunosensor based on an ionic organic molecule and chitosan-stabilized gold nanoparticles for the detection of cardiac troponin T.

نویسندگان

  • Daniela Brondani
  • Jamille Valéria Piovesan
  • Eduard Westphal
  • Hugo Gallardo
  • Rosa Amalia Fireman Dutra
  • Almir Spinelli
  • Iolanda Cruz Vieira
چکیده

A label-free electrochemical immunosensor based on an ionic organic molecule ((E)-4-[(4-decyloxyphenyl)diazenyl]-1-methylpyridinium iodide) and chitosan-stabilized gold nanoparticles (CTS-AuNPs) was developed for the detection of cardiac troponin T (cTnT). The new ionic organic molecule was strategically employed as a redox probe, and CTS-AuNPs were applied as a "green" platform for the immobilization of the monoclonal anti-cTnT antibody, for the construction of the immunosensor. The characterization of the proposed immunosensor was carried out by employing cyclic and square-wave voltammetry and electron microscopy. The film of ionic organic molecules acts as a redox probe and from its electrochemical response the presence of cTnT antigens, which interact specifically with the anti-cTnT antibody immobilized on the surface of the immunosensor, can be detected. This interaction results in a decrease in the analytical signal, which is proportional to the amount of cTnT antigens present in the sample analyzed. Under optimized conditions, using square-wave voltammetry (a frequency of 100 Hz, an amplitude of 100 mV and an increment of 8 mV) and an incubation time of 10 min, the proposed immunosensor showed linearity in the range of 0.20 to 1.00 ng mL(-1) cTnT, with a calculated limit of detection of 0.10 ng mL(-1). The proposed immunosensor shows some advantages when compared to other sensors reported in the literature, especially with regard to the detection limit and the time of incubation. A study of the interday precision (n = 8) showed a coefficient of variation of 3.33%. The potential interference of some compounds (glucose, ascorbic acid, albumin, uric acid, creatine, and creatinine) on the response of the immunosensor was evaluated and the inhibition of the immunosensor response was found to be less than 8.0%. The immunosensor was successfully used for the determination of cTnT in samples of simulated blood serum with a relative error of <13.0%. Furthermore, the proposed methodology provides a working range that allows the detection of cTnT antigens at levels below the cutoff value used for the diagnosis of acute myocardial infarction and was also found to be faster than the conventional methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction

Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI.Objectives: In this study, a molecular method is introduced to early diagnosis of MI by rapid detection of TnI.Materials and Methods: The detection method was based on electrochemical aptasens...

متن کامل

Using Boehmite Nanoparticles as an Undercoat, and Riboflavin as a Redox Probe for Immunosensor Designing: Ultrasensitive Detection of Hepatitis C Virus Core Antigen

In this study a label-free electrochemical Immunosensor for ultrasensitive detection of Hepatitis C virus core antigen in serum samples was fabricated by using a simple approach. In this method a low-cost and sensitive immunosensor was fabricated based on a boehmite nanoparticles (BNPs) modified glassy carbon. The BNPs provide a specific platform with increased surface area which is capable of ...

متن کامل

Fabrication of an Electrochemical Immunosensor for Determination of Human Chorionic Gonadotropin Based on PtNPs/Cysteamine/AgNPs as an Efficient Interface

An ultrasensitive electrochemical immunosensor for the detection of tumor marker human chorionic gonadotropin (hCG) was developed with a limit of detection as low as 2 pg mL-1 in phosphate buffer. The Platinum nanoparticles (PtNPs) were electrodeposited to modify the gold surface and to increase enlarging the electrochemically active sites, resulting in the facilitation of electron exchange. Cy...

متن کامل

Designing a Label Free Aptasensor for Detection of Methamphetamine

A label-free electrochemical nucleic acid aptasensor for the detection of methamphetamine (MA) by the immobilization of thiolated self-assembled DNA sequences on a gold nanoparticles-chitosan modified electrode is constructed. When MA was complexed specifically to the aptamer, the configuration of the nucleic acid aptamer switched to a locked structure and the interface of the biosensor changed...

متن کامل

Electrochemical immunosensor for carcinoembryonic antigen based on antigen immobilization in gold nanoparticles modified chitosan membrane.

A disposable electrochemical immunosensor for carcinoembryonic antigen (CEA) was proposed based on the antigen immobilized in a colloidal gold nanoparticles modified chitosan membrane on the surface of an indium-tin oxide (ITO) electrode. The different membranes were characterized by scanning electron microscope and electrochemical methods. Based on a competitive immunoassay format, the immobil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 139 20  شماره 

صفحات  -

تاریخ انتشار 2014