Three-dimensional coronary sinus reconstruction-guided left ventricular lead implantation based on intraprocedural rotational angiography: a novel imaging modality in cardiac resynchronization device implantation.

نویسندگان

  • Klaus-Jürgen Gutleben
  • Georg Nölker
  • Guido Ritscher
  • Harald Rittger
  • Christopher Rohkohl
  • Günter Lauritsch
  • Johannes Brachmann
  • Anil Martin Sinha
چکیده

AIMS Rotational angiography (RA) of the coronary sinus (CS) provides more anatomical insights compared with static angiographies. We evaluated intraprocedural three-dimensional (3D) CS reconstruction (RC) based on RA, using syngo(®) DynaCT Cardiac to guide CS lead implantation. METHODS AND RESULTS In 24 patients with indication for cardiac resynchronization therapy, intraprocedural RA and 3D RC of the CS was performed. Lead placement was guided by 3D image integration into real-time fluoroscopy. Rotational angiography and 3D RCs were evaluated regarding visibility of the CS and tributaries, CS-to-target vein angles, and vessel diameters. The target vein for CS lead implantation, identified by RA, was successfully displayed by 3D RC in 20 (91%) of 22 patients with adequate RA. All lead implantations were guided successfully by 3D image integration into real-time fluoroscopy. Cranial or caudal angulations were used in 95% of the procedures without further angiographies. Rotational angiography displayed a mean of 2.9 ± 1.0 second-order side branches compared with 1.8 ± 1.1 in 3D RCs (P< 0.05). The CS-to-target vein angle estimated from static projections (right anterior oblique 20°, left anterior oblique 40°, and even optimal RA view) differed substantially from 3D RCs. Main vessel diameters did not differ significantly between both techniques. CONCLUSION Intraprocedural 3D RC of the CS and 3D image integration-guided lead placement is feasible. Coronary sinus-to-target vein angles seemed to be misestimated even by RA views compared with 3D RC. Thus RA and 3D CS RC should be applied routinely for CS lead implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetically guided left ventricular lead implantation based on a virtual three-dimensional reconstructed image of the coronary sinus

AIMS Left ventricular (LV) lead implantation is feasible using remote magnetic navigation of a guidewire (Stereotaxis, St Louis, MO, USA). A novel software that performs a three-dimensional (3D) reconstruction of vessels based on two or more angiographic views has been developed recently (CardiOp-B system, Paeion Inc., Haifa, Israel). The objective of this paper is to evaluate: (i) the performa...

متن کامل

A novel cardiac MRI protocol to guide successful cardiac resynchronization therapy implantation.

Cardiac MRI (CMR) is recognized as an important imaging modality for assessing patients with heart failure. With improved segmentation and image registration tools, data acquired using CMR can help with planning and intraprocedural guidance as well as with defining etiology of heart failure and ventricular function. Here, we describe a successful CRT implantation where segmented CMR images were...

متن کامل

Implantation of a cardiac resynchronization therapy-defibrillator device in a patient with persistent left superior vena cava.

Presence of a persistent left superior vena cava (PLSVC) is generally clinically asymptomatic and discovered incidentally during central venous catheterization. However, PLSVC may cause technical difficulties during cardiac device implantation. An 82-year-old man with heart failure symptoms and an ejection fraction (EF) of 20% was scheduled for resynchronization therapy-defibrillator device (CR...

متن کامل

Cardiac resynchronization therapy device implantation guided by electroanatomic mapping system when contrast medium infusion is contraindicated

Introduction The implantation of transvenous leads for pacemakers and defibrillators is traditionally performed using fluoroscopic guidance. When cardiac resynchronization therapy (CRT) is indicated, iodine contrast medium (ICM) infusion for coronary sinus (CS) branch visualization is also needed. Adverse reactions to ICM during cardiac catheterization and coronary interventions are common. Chr...

متن کامل

Usefulness of hyperemic venous return angiography for studying coronary venous anatomy prior to cardiac resynchronization device implantation.

INTRODUCTION AND OBJECTIVES Implantation of electrodes via the coronary sinus (CS) can be very challenging because access to the target vessel is restricted by anatomical obstacles. Consequently, prior knowledge of coronary venous anatomy is crucial. The objective of this study was to evaluate the usefulness of hyperemic venous return angiography relative to that of occlusive retrograde venogra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 2011