One-year coronary bypass graft patency: a randomized comparison between off-pump and on-pump surgery angiographic results of the PRAGUE-4 trial.
نویسندگان
چکیده
BACKGROUND Off-pump coronary bypass surgery has become a widely used technique during recent years. However, limited data are available with regard to 1-year patency of bypass grafts implanted on the beating heart in unselected consecutive bypass surgery candidates. The aim of this study was to compare 1-year angiographic patency of bypass grafts done on the beating heart (off pump) with those done classically (on pump). METHODS AND RESULTS The PRAGUE-4 trial randomized 400 consecutive nonselected cardiac surgery candidates into group A (on pump; n=192) and group B (off pump; n=208). One-year follow-up coronary angiography was done in 255 patients. The arterial graft patency after 1 year was 91% in both groups. Saphenous graft patency was 59% (on pump) versus 49% (off pump; P=NS). Saphenous graft patency per patient was lower in the off-pump group: 0.7 patent anastomosis per patient versus 1.1 patent anastomosis in the on-pump group (P<0.01). There were 46% on-pump patients with all grafts patent versus 52% off-pump patients (P=NS). Grafts anastomosed distally to collateralized chronic total occlusions of native coronary arteries remained patent in 100% on the left anterior descending artery compared with 23% on other arteries (P<0.0001). CONCLUSIONS The patency of arterial coronary bypass grafts done on the beating heart is excellent and equal to grafts done on pump. The off-pump procedure in the unselected patient population results in fewer patent saphenous grafts per patient.
منابع مشابه
Comparison of Unstable Hemodynamic Patients Undergoing Coronary Artery Bypass Graft Surgery with on- or off-Pump Methods
Introduction: Coronary artery disease (CAD) is the most common type of heart disease, with a mortality rate of 385,000 person per year in the United States. There are two main methods for CAD treatments: angioplasty and bypass surgery. Coronary Artery Bypass Grafting (CABG) is one of the greatest surgical operations of the 20th century and it is presented as most effective and long-term therapi...
متن کاملCardiovascular Surgery Off-Pump Coronary Artery Bypass Surgery Is Associated With Worse Arterial and Saphenous Vein Graft Patency and Less Effective Revascularization
Background—The Department of Veterans Affairs Randomized On/Off Bypass (ROOBY) trial compared clinical and angiographic outcomes in off-pump versus on-pump coronary artery bypass graft (CABG) surgery to ascertain the relative efficacy of the 2 techniques. Methods and Results—From February 2002 to May 2007, the ROOBY trial randomized 2203 patients to off-pump versus on-pump CABG. Follow-up angio...
متن کاملOff-Pump Coronary Artery Bypass Surgery Is Associated With Worse Arterial and Saphenous Vein Graft Patency and Less Effective Revascularization
Background—The Department of Veterans Affairs Randomized On/Off Bypass (ROOBY) trial compared clinical and angiographic outcomes in off-pump versus on-pump coronary artery bypass graft (CABG) surgery to ascertain the relative efficacy of the 2 techniques. Methods and Results—From February 2002 to May 2007, the ROOBY trial randomized 2203 patients to off-pump versus on-pump CABG. Follow-up angio...
متن کاملEmergency Conversion from Off Pump to Cardiopulmonary Bypass in Patients with Coronary Artery Bypass Graft Surgery
Introduction: As off pump Coronary artery bypass grafting surgery (CABG) is a developing method in coronary cardiac surgery, most surgeons are anxious about the danger of emergency crash conversion. In this observational study we tried to show the rate and outcome of conversion . Material and methods: In this descriptive study about 477 coronary off-pump CABG patients were operated in Ghaem hos...
متن کاملOff-Pump coronary artery bypass surgery is associated with worse arterial and saphenous vein graft patency and less effective revascularization: Results from the Veterans Affairs Randomized On/Off Bypass (ROOBY) trial.
BACKGROUND The Department of Veterans Affairs Randomized On/Off Bypass (ROOBY) trial compared clinical and angiographic outcomes in off-pump versus on-pump coronary artery bypass graft (CABG) surgery to ascertain the relative efficacy of the 2 techniques. METHODS AND RESULTS From February 2002 to May 2007, the ROOBY trial randomized 2203 patients to off-pump versus on-pump CABG. Follow-up ang...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 110 22 شماره
صفحات -
تاریخ انتشار 2004