Improved detection and localization of lower gastrointestinal hemorrhage using subtraction scintigraphy: clinical evaluation.

نویسندگان

  • Geoffrey M Currie
  • Philip A Towers
  • Janelle M Wheat
چکیده

UNLABELLED Does subtraction scintigraphy improve the diagnostic utility of scintigraphic evaluation in acute lower gastrointestinal hemorrhage? METHODS This research was a retrospective clinical study using a repeat-measures design of randomized control and experimental groups. A single patient dataset provided both the control group (conventional scintigraphy) and the experimental group (conventional and subtraction techniques). Forty-nine raw (99m)Tc-red blood cell studies were randomized and interpreted by 4 independent physicians as conventional scintigraphy data only (round 1). The conventional scintigraphy studies were combined with subtraction images and randomized for reinterpretation (round 2). RESULTS Although there was a decrease in the mean, no statistically significant difference was noted between the mean time to bleed detection between interpretive rounds 1 and 2 (P = 0.524). The addition of subtraction scintigraphy to the interpretation process changed the outcome from "probably present" to "absent" for 14% of patients and from "equivocal" to "absent" for another 12%, and this change had a marked effect on the false-positive rate. The false-positive rate decreased from 9.6% in round 1 to 3.6% in round 2. Receiver operator characteristic analysis showed that combining conventional scintigraphy with subtraction scintigraphy improved test performance. CONCLUSION False-positive studies can be reduced by using subtraction scintigraphy in conjunction with conventional scintigraphy in the interpretive process.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved detection and localization of lower gastrointestinal tract hemorrhage by subtraction scintigraphy: phantom analysis.

UNLABELLED Acute lower gastrointestinal tract hemorrhage (LGIH) has significant morbidity and mortality outcomes. Although several causes of LGIH can be life threatening, most can be effectively treated; therefore, early detection and accurate localization of bleeding sites are critical for successful patient management. METHODS This study was a phantom experimental study with a repeated-meas...

متن کامل

Cost-effectiveness analysis of subtraction scintigraphy in patients with acute lower gastrointestinal tract hemorrhage.

UNLABELLED (99m)Tc-labeled red blood cell scintigraphy is a powerful detection and localization tool that may be confounded by false-positive and false-negative findings. Subtraction scintigraphy has been used in the evaluation of acute lower gastrointestinal tract hemorrhage (LGIH) to reduce the impact of interpretive confounders. The aim of this investigation was to evaluate the cost-effectiv...

متن کامل

A Gastrointestinal Bleed Detected On Subtraction Scintigraphy: A Case Study

This article reports an interesting case of lower gastrointestinal hemorrhage (LGIH) detected using subtraction imaging on Tc RBC scintigraphy.

متن کامل

Accuracy of 99mTechnetium-labeled RBC Scintigraphy and MDCT With Gastrointestinal Bleed Protocol for Detection and Localization of Source of Acute Lower Gastrointestinal Bleeding.

BACKGROUND Acute lower gastrointestinal bleeding (LGIB) is a major cause of morbidity and mortality. Multidetector row computed tomography (CT) with gastrointestinal (GI) bleed protocol is a novel diagnostic technique for detecting and localizing LGIB. Being rapid and noninvasive, it may be useful as a first-line modality to investigate cases of acute LGIB. GOALS To assess and compare diagnos...

متن کامل

Scintigraphy of patient with hematochezia.

Gastrointestinal bleeding can result in significant morbidity. Scintigraphy plays an important role in detecting, localizing, and grading the bleed. Effective scintigraphic evaluation of gastrointestinal bleeding can be complicated by its intermittent nature and the patient's hemodynamic instability. Dynamic evaluation, delayed imaging, and an understanding of the labeling process are necessary...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 2007