Effects of equipment and technique on peak flow measurements

نویسندگان

  • Thomas Bongers
  • B Ronan O'Driscoll
چکیده

BACKGROUND Different lung function equipment and different respiratory manoeuvres may produce different Peak Expiratory Flow (PEF) results. Although the PEF is the most common lung function test, there have been few studies of these effects and no previous study has evaluated both factors in a single group of patients. METHODS We studied 36 subjects (PEF range 80-570 l/min). All patients recorded PEF measurements using a short rapid expiration following maximal inspiration (PEF technique) or a forced maximal expiration to residual volume (FVC technique). Measurements were made using a Wright's peak flow meter, a turbine spirometer and a Fleisch pneumotachograph spirometer. RESULTS The mean PEF was 8.7% higher when the PEF technique was used (compared with FVC technique, p < 0.0001). The mean PEF recorded with the turbine spirometer was 5.5% lower than the Wright meter reading. The Fleisch spirometer result was 19.5% lower than the Wright reading. However, adjustment of the Wrights measurements from the traditional Wright's scale to the new EU Peak Flow scale produced results that were only 7.2% higher than the Fleisch pneumotachograph measurements. CONCLUSION Peak flow measurements are affected by the instruction given and by the device and Peak Flow scale used. Patient management decisions should not be based on PEF measurement made on different instruments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peak Expiratory Flow Rate in Healthy Children from Tehran

Background: Measuring peak expiratory flow rate has been suggested as an important tool in asthma management by all international guidelines.  Objective: Studies on various populations have shown considerable variations in normal values of peak expiratory flow rate. Since reference standards for Iranian children are not available, the present study was performed to establish these standards. Me...

متن کامل

Improvement of Hydrodynamics Performance of Naphtha Catalytic Reforming Reactors Using CFD

Due to high applicability of the fixed bed catalytic naphtha reforming reactors, hydrodynamic features of this kind of reactors with radial flow pattern are improved in this work by utilising computational fluid dynamics technique. Effects of catalytic bed porosity, inlet flow rate and flow regime through the bed on the flow distribution within the system are investigated.It is found that t...

متن کامل

Identifying Significant Health Measurement of Equipment Affecting the Quality of a Continuous Product (Case Study: Unit 2, Parand Gas Turbine Power Plant)

Objective: Majorproducers consider quality as a major criterion in decision making.Quality characteristics are affected by maintenance and repair decisions. In this study, a model is developed to determine significant measurements of production equipment affecting the quality of a continuous product to identify which measurements are more critical in terms of quality. Methods: Diversity of par...

متن کامل

Instant effects of peppermint essential oil on the physiological parameters and exercise performance

Objective: Effect of peppermint on exercise performance was previously investigated but equivocal findings exist. This study aimed to investigate the effects of peppermint ingestion on the physiological parameters and exercise performance after 5 min and 1 h. Materials and Methods: Thirty healthy male university students were randomly divided into experimental (n=15) and control (n=15) groups. ...

متن کامل

Effects of Ramadan fasting on spirometric values and clinical symptoms in asthmatic patients

Introduction: Ramadan is the 9th  Islamic lunar month during which Muslims avoid eating and drinking from sunrise to sunset.  The effect of Ramadan intermittent fasting on asthma control is controversial.  The aim of this study was to investigate the effects of Ramadan fasting on the spirometric variables and clinical symptoms on well-controlled asthmatic patients during Ramadan. Material and M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Pulmonary Medicine

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2006