A computer-controlled potentiometric/spectrophotometric titrator

نویسنده

  • John D. Stong
چکیده

A laboratory computer controlled potentiometric titrator interfaced to a diode array spectrophotometer is described. The titrator consists of widely used, commercially available components; therefore, major attention is given to modes of interconnection and software implementation in data format and system control. Replicate potentiometric titrations of glycines gave a relative standard deviation in titre of 1.035% and a relative standard deviation in pH of 0.745%. Replicate spectrophotometric titrations of bromophenol blue were analysed at three wavelengths to yield pKa= 3.898 +/- 0.075 (1.9% rsd).Methods of data presentation and manipulation are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potentiometric and Spectrophotometric Determination of Phenothiazine Derivatives Based on Their Titration with 2,3-dichloro-5,6-dicyano-1,4-benzoquinone

The reaction between phenothiazine and 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) in the presence of p-toluenesulfonic acid in chloroform was investigated by potentiometry, voltammetry and spectrophotometry, and the reaction pathways were proposed. The conditions for the oxidimetric titration of phenothiazines with a standard chloroform solution of DDQ were optimized and the potentiometric...

متن کامل

Potentiometric and spectrophotometric determination of the protonation constant of hexamethylenetetramine.

The protonation constant of hexamethylenetetramine (urotropine) was determined by a potentiometric and a spectrophotometric method. The calculations gave log K(HL) (concentration constants): 4.89 at mu = 0.1 and 5.05 at mu = 0.5. The temperature was 25 degrees and potassium chloride was used to adjust the ionic strength.

متن کامل

pH-based Detection of Phenylalnine by Potentiometric and Colorimetric Methods

In this paper, methods of sample preparation for potentiometric measurement of phenylalanine are presented. Basing on the spectrophotometric measurements of phenylalanine, the concentrations of reagents of the enzymatic reaction (10 mM L-Phe, 0,4 mM NAD, 2U L-PheDH) were determined. Then, the absorption spectrum of the reaction product, NADH, was monitored (maximum peak at 340 nm). The results ...

متن کامل

A PC-based titrator for flow gradient titrations

This paper describes a PC (personal computer) based titrator which was developed for gradient flow titrations. Concentration gradients were generated electrolytically or volumetrically in small tubes. Complete titration curves can be recorded on-line and evaluated automatically. The titrator can be used with all liquid flow detectors with low axial dispersion. The titrator was evaluated for the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 10  شماره 

صفحات  -

تاریخ انتشار 1988