Permanent pacemaker insertion in a district general hospital: indications, patient characteristics, and complications.

نویسندگان

  • A Eltrafi
  • P Currie
  • J H Silas
چکیده

UNLABELLED This report reviews the experience of permanent pacemaker insertion in a district general hospital (catchment population of 350 000) and makes a comparison with the national database and other hospitals in the UK. METHODS The records of all patients receiving a permanent pacemaker in the inclusive period January 1996 to December 1998 were reviewed. Data collected included number of patients paced each year, age, sex, indications, and complications. RESULTS In the three years reviewed 200 patients received new permanent pacemakers, a rate of 190 per million population per year, which is similar to the national implantation rate of permanent pacemakers but lower than that of most European countries (see discussion). The majority of patients paced were elderly (75% were above the age of 70 years). Atrioventricular block (including complete heart block, 45%, and Mobitz type 2 block, 12.5%) was the commonest indication for permanent pacemaker insertion, followed by sick sinus syndrome (25%) and these findings are comparable to those reported previously. However, carotid sinus syndrome was responsible for 16% of the patients paced and this was higher than that reported in the national database (6.5%). Only 1% of the pacemaker modes used was inappropriate and the complication rate was low at 3%. CONCLUSIONS This report confirms that permanent pacemaker insertion can be effectively and safely provided locally for the increasingly ageing population. The implantation rate both locally and nationally is still much lower than that of some countries in Europe.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE ROLE OF PACEMAKER CLINIC IN THE FOLLOW-UP OF PATIENTS WITH PERMANENT PACEMAKERS

The Pacemaker Clinic at Shahid Rajai Cardiovascular Research Center first started operating in August 1992. In its first year of operation, 294 permanent pacemaker patients were studied, allowing an appraisal to be carried out of the clinic's effectiveness in diagnosing and treating early complications. In the final analysis, pacemaker complications were observed in 68 (23%) patients, of wh...

متن کامل

Permanent pacemaker practice at a Scottish district general hospital between 1987 and 1993.

BACKGROUND Raigmore is a district general hospital offering a permanent pacemaker service to its catchment population of 233,500. It has been argued that the British public would be better served by a less centralised pacing service. There also exists the view, however, that a lower rate of complications and best follow up practice are achieved by specialised centres. The pacemaker practice ove...

متن کامل

Correcting a block? Successful experience of a small British pacing centre.

The establishment of a local permanent pacemaker service in a district general hospital increased the pacemaker implantation rate from 22 per million population per year to 152 per million population per year over the first 6 years of the service. Forty eight per cent of patients were referred by general practitioners and 52% by hospital specialists. Single chamber demand pacing (VVI) was used ...

متن کامل

Comparing the early function and complications between fluoroscopic guidance and blindly insertion of permanent hemodialysis catheter

Objective: Chronic kidney disease (CKD) is a complicated kidney defect causing permanent failure in renal function in progressive stages. Hemodialysis is the most accepted treatment to maintain body’s fluid/electrolyte homeostasis at the terminal stages of the disease. Permanent hemodialysis catheter (permicath) may be inserted blindly or by fluoroscopic guidance. This study aimed to compare th...

متن کامل

ffect of Chlorhexidine on Prevention of Local Infection in Temporary Transvenous Pacemaker Catheter Site

Background and Objectives: The local infection of temporary transvenous pacemaker catheter site is a common hospital acquired infections. This study aimed to assess the effect of the Chlorhexidine Glaciate 2% on prevention of local infection on temporary transvenous pacemaker catheter site. Materials and Methods: In this 7-month randomized controlled trial, 100 patients having temporary transve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Postgraduate medical journal

دوره 76 896  شماره 

صفحات  -

تاریخ انتشار 2000