Beyond screening for risk factors: objective detection of strabismus and amblyopia.

نویسندگان

  • Reed M Jost
  • Susan E Yanni
  • Cynthia L Beauchamp
  • David R Stager
  • David Stager
  • Lori Dao
  • Eileen E Birch
چکیده

IMPORTANCE Commercially available automated vision screening devices assess refractive risk factors, not amblyopia or strabismus, underreferring affected children and overreferring healthy children. Nearly half of affected children are not identified until after age 5 years, when treatment is less effective. OBJECTIVES To determine the diagnostic accuracy of the Pediatric Vision Scanner (PVS), a binocular retinal birefringence scanner, to objectively identify strabismus and amblyopia, and to compare retinal birefringence screening with a widely used automated pediatric screening device. DESIGN, SETTING, AND PARTICIPANTS Three hundred consecutive preschool children (aged 2-6 years) were screened using the PVS and the SureSight Autorefractor at 2 pediatric ophthalmology private practices. A masked comprehensive pediatric ophthalmic examination provided the gold standard for determining sensitivity and specificity for each screening device. MAIN OUTCOMES AND MEASURES The primary outcome was sensitivity and specificity of the PVS for detecting the targeted conditions, strabismus and amblyopia, in children aged 2 to 6 years. Secondary outcomes included the positive and negative likelihood ratios of the PVS for identifying the targeted conditions. In addition, sensitivity, specificity, and positive and negative likelihood ratios of the SureSight Autorefractor for the targeted conditions were assessed in the same cohort of children. RESULTS Of the 300 patients, 188 had strabismus only, amblyopia only, or both, and 112 had no strabismus or amblyopia. The sensitivity of the PVS to detect strabismus and amblyopia (0.97; 95% CI, 0.94-1.00) was significantly higher than that of the SureSight Autorefractor (0.74; 95% CI, 0.66-0.83). Specificity of the PVS for strabismus and amblyopia (0.87; 95% CI, 0.80-0.95) was significantly higher than that of the SureSight Autorefractor (0.62; 95% CI, 0.50-0.73). CONCLUSIONS AND RELEVANCE The PVS identified children with strabismus and/or amblyopia with high sensitivity, outperforming the SureSight Autorefractor. Accurate, early detection of these conditions could improve long-term vision outcomes of affected preschool children.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid, high-accuracy detection of strabismus and amblyopia using the pediatric vision scanner.

Purpose. The Pediatric Vision Scanner (PVS) detects strabismus by identifying ocular fixation in both eyes simultaneously. This study was undertaken to assess the ability of the PVS to identify patients with amblyopia or strabismus, particularly anisometropic amblyopia with no measurable strabismus. Methods. The PVS test, administered from 40 cm and requiring 2.5 seconds of attention, generated...

متن کامل

Guidelines for automated preschool vision screening: a 10-year, evidence-based update.

In 2003 the American Association for Pediatric Ophthalmology and Strabismus Vision Screening Committee proposed criteria for automated preschool vision screening. Recent literature from epidemiologic and natural history studies, randomized controlled trials of amblyopia treatment, and field studies of screening technologies have been reviewed for the purpose of updating these criteria. The prev...

متن کامل

Performance of the Plusoptix A09 Photoscreener in Detecting Amblyopia Risk Factors in Chinese Children Attending an Eye Clinic

PURPOSE To assess the accuracy of the Plusoptix A09 photoscreener in detecting amblyopia risk factors in children and determine referral criteria when using Plusoptix A09 for a large-scale vision screening. METHODS Pediatric patients attending our eye clinic underwent a comprehensive ophthalmic examination that included photorefraction, orthoptic examination, anterior segment assessment, fund...

متن کامل

2000 journal of the american association for pediatric ophthalmology and strabismus

The AAPOS Vision Screening Committee established the first guidelines for automated preschool vision screening in 2003. These primarily addressed the magnitude of refractive error that was (by consensus) thought to put a child at risk for the development of amblyopia. Since then, more data have emerged about the prevalence of amblyopia risk factors in young children from which it is clear that ...

متن کامل

The Pediatric Vision Screener III: detection of strabismus in children.

OBJECTIVE To evaluate the clinical performance of the Pediatric Vision Screener (PVS) in children in a pediatric ophthalmology office setting. METHODS Seventy-seven subjects between 2 and 18 years of age received gold-standard orthoptic examinations and were classified as at risk for amblyopia if strabismus or anisometropia (>1.50 diopters) was present. Strabismus was subclassified as variabl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JAMA ophthalmology

دوره 132 7  شماره 

صفحات  -

تاریخ انتشار 2014