Effects of relaxation during RF pulses on the homogeneity of signal intensity in parallel transmission

نویسندگان

  • M. Sekino
  • N. Boulant
  • M. Luong
  • A. Amadon
  • H. Ohsaki
  • D. Le Bihan
چکیده

Introduction: Counteracting the inhomogeneity of the RF excitation is one of the technical challenges in high-field MRI. Dynamic RF shimming techniques in combination with parallel transmission have shown to be quite powerful for mitigating B1 inhomogeneity [1, 2]. So far to our knowledge, these methods have been uniquely based on the spins’ coherent dynamics, and do not account for relaxation during the RF pulses. Because the pulse duration can be on the order of a few milliseconds, relaxation can in fact lead to a degradation of signal uniformity via an alteration of the flip angle (FA) distribution but also via a non-uniform attenuation of the magnetization vector. For short T2, large T1 and short TR sequences, these effects should be assessed. The key is to realize that one to some percent attenuation of the magnetization vector can be comparable to E1=exp(-TR/T1) and can therefore have drastic effects on the measured signal intensity and homogeneity. In this study, we numerically investigate at 7 T the degradation of the spoiled gradient echo (SPGE) signal homogeneity when designing a transmit-SENSE pulse aimed at homogenizing only the FA over an axial slice of a human head. Although the final uniformity may still be very good, we show that the signal inhomogeneity can sometimes deteriorate by a factor of 10 because of relaxation and should worsen even more at higher fields. The effect seems mostly noticeable around the Ernst flip angle. Methods: We modeled an RF coil with a length of 340 mm and an inner diameter of 270 mm using the Ansoft HFSS software, which incorporated a human head model produced by the Aarkid company. The coil consisted of 8 emitting half-wave dipole-type antennas. RF electromagnetic fields were calculated with a spatial resolution of 5 mm and a frequency of 300 MHz. Figures 1(a)(b) show the magnitude and the phase of the transmitted B1 field for one channel. RF and gradient waveforms were designed using the transmit-SENSE and spokes method [1, 2] to homogenize the flip angle over a 3 mm thick axial slice located at the center of the RF coil. The five spokes were located at (0, 0), (k0, k0), (–k0, k0), (k0, –k0), and (–k0, –k0) with a displacement of k0 = 22.2 m , a length of 6283 m, and total duration of 3.8 ms. RF waveforms were designed based on the small-flip-angle approach [1, 2] with an acceleration factor of 1.0 and Tikhonov regularization parameters λ of 0.01 and 10, to give a target flip angle of 5 degrees. Magnitude least squares optimization using the local variable exchange method was performed to improve the homogeneity of the magnetization profile [3]. For higher flip angles, the RF waveforms were simply scaled. For each target flip angle and regularization parameter, Bloch equation with and without relaxation terms was integrated numerically to yield in each voxel a flip angle and a magnitude of the magnetization vector. T1 and T2 were taken to be respectively 2000 and 59 ms, which correspond to gray matter at 7 T [4]. These calculated values were then inserted in the following formula to calculate the signal intensity, accounting for relaxation, in a SPGE sequence: S(n,θ)∝ (1-E1) n sinθ/(1n E1cosθ), where θ is the flip angle and n is the length of magnetization after RF excitation normalized by the one before excitation. TR was also varied to scan a large range of experimental parameters. Results and Discussion: As shown in Fig. 1.c, the optimized RF waveforms were similar to a series of sinc functions because the target profile was uniform in the selected slice. As an example, Fig. 2 shows the distribution of the length of magnetization after RF excitation and of the flip angle for λ=0.01, and for a target FA=10°. Relaxation caused in this case an increase in the inhomogeneity of FA from 3.9 % to 4.5 % (see Fig. 3.a), while the average attenuation of the magnetization vector was 0.13 % with standard deviation of 0.062 %. In this example, the degradation of signal homogeneity (see Fig. 4. b), quantified by std/mean over the targeted slice, is primarily due to a difference in the FA distribution. In addition, Fig. 3.a shows that when λ is large enough, no severe degradation in the FA distribution due to the small tip angle approximation occurs and relaxation barely affects the uniformity of the FA. Furthermore, Fig. 3.b shows an increase and decrease of the dispersion of the values of n with respect to the FA and λ respectively. The larger the FA and the smaller λ are, the larger the excursion of the spin vectors from the z-axis during the pulse is and the more they shrink because of T2. As a result, at higher flip angles, a degradation of signal uniformity due to relaxation during the pulses is mainly caused by an increased variability of n. For instance at 45°, the mean and std of n were calculated to be 2.0 % and 0.7 %. Although these are small numbers, inserted in the S(n,θ) formula above, they can sometimes have a large impact (depending on the value of E1). We plot in Fig. 4.a. and 4.b. respectively the signal intensity S(n,θ) and inhomogeneity for the SPGE sequence, for λ=0.01, for several values of TR and again, with and without relaxation terms in our simulations. The loss of signal and degradation of signal uniformity are mostly noticeable around the Ernst angle, with 4.3 % of signal loss (TR=100 ms) and an increased signal inhomogeneity by a factor of 10 (TR=30 ms at FA=10°). While this relative effect is large, the absolute effect is still small (0.19 % without relaxation, 1.9 % with relaxation). Conclusion: In this study we have shown that relaxation effects during RF pulses can have a relatively large effect in SPGE sequences when designing B1 pulse compensation schemes on the order of a few milliseconds. As the external magnetic field increases, T1 and T2 tend to respectively increase and decrease. It is therefore likely to become more and more important at higher fields. Last, it was shown that the Tikhonov regularization parameter could, in addition to decreasing the RF energy, also have a large impact on the effect of relaxation during the RF pulses. References: [1] Saekho S. et al, Magn Reson Med 2006;55:719-724. [2] Grissom W. et al, Magn Res Med 2006;56:620-629. [3] Setsompop K. et al, Magn Reson Med 2008;59:908-915. [4] Pfeuffer J. et al, Magn Reson Imag 2004;10:1343-1359.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

SAR Reduction in Parallel Transmission by k-Space Dependent RF Pulse Selection

Parallel transmission has gained considerable interest during the last few years [1,2]. The use of multiple individual RF transmit coils have been introduced to overcome B1 homogeneity limitations and to improve multi-dimensional RF pulses by shortening their duration. Of special concern in all these transmit applications is the specific absorption rate (SAR), which has to be kept below certain...

متن کامل

T2*-compensated Transmit SENSE RF pulses

Introduction Selective excitation in more than one dimension is plagued by effects that are due to the long duration of the RF pulses and gradient trajectories needed. B0 off-resonances, for example, dephase magnetization contributions created at different points in time during the excitation process. As a consequence, these contributions do not add up consistently which causes artifacts in the...

متن کامل

Transmit Arrays and Circuitry

For body dimensions at 3T and head dimensions at 7T and above the RF wavelength in dielectric tissue is comparable or smaller than the dimensions of the human anatomy. This in turn leads to RF phase related traveling time differences, prominent wave behavior and the potential for a significant difference between transmit B1 + and receive B1 fields [5-10]. It is possible to correct some of the r...

متن کامل

Parallel RF transmission in body MRI for reduced dielectric shading, improved B1 homogeneity and accelerated imaging at 3.0T: Initial clinical experience in 40 patients using MultiTransmit

Introduction Electromagnetic wave propagation in tissue is known to cause dielectric resonance effects if the wavelength reaches the object dimension. At 3.0T, dielectric resonance effects are visible in body MR imaging predominantly in heavier patients and in patients with intraabdominal fluid collections (i.e. ascites). The use of multiple transmit channels can provide better control of the r...

متن کامل