Biological effects of soft denture reline materials on L929 cells in vitro

نویسندگان

  • Carolina AL Chaves
  • Carlos E Vergani
  • Dominique Thomas
  • Anne Young
  • Carlos AS Costa
  • Vehid M Salih
  • Ana L Machado
چکیده

Soft denture reline materials have been developed to help patients when their oral mucosa is damaged or affected due to ill-fitting dentures or post-implant surgery. Although reports have indicated that these materials leach monomers and other components that do affect their biocompatibility, there is little information on what cell molecules may be implicated in these material/tissue interactions. The biocompatibility of six soft liners (Ufi Gel P, Sofreliner S, Durabase Soft, Trusoft, Softone and Coe Comfort) was evaluated using a mouse fibroblast cell line, L929. Within 2 h of material disc preparation, each of the materials was exposed by direct contact to L929 cells for periods of 24 and 48 h. The effect of this interaction was assessed by alamarBlue assay (for cell survival). The expression of integrin α5β1 and transforming growth factor β1 was also assessed using plate assays such as enzyme-linked immunosorbent assay. Trusoft, Softone and Coe Comfort showed significantly reduced cell survival compared with the other soft lining materials at each incubation period. Furthermore, there were significant differences with these same materials in the expression of both integrin α5β1 and transforming growth factor β1. Soft liner materials may affect cell viability and cellular proteins that have important roles in wound healing and the preservation of cell viability and function in the presence of environmental challenges and stresses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tensile and shear bond strength of hard and soft denture relining materials to the conventional heat cured acrylic denture base resin: An In-vitro study.

BACKGROUND The condition of the denture bearing tissues may be adversely affected by high stress concentration during function. Chairside Denture (Hard and Soft) reliners are used to distribute forces applied to soft tissues during function. Tensile and shear bond strength has been shown to be dependent on their chemical composition. A weak bond could harbor bacteria, promote staining and delam...

متن کامل

Effect of denture cleansers on Candida albicans biofilm formation over resilient liners

PURPOSE The purpose of this study was to analyze the effect of denture cleansers on Candida albicans biofilm formation over resilient liners and to evaluate compatibility between resilient liners and denture cleansers. MATERIALS AND METHODS Acrylic resin (Lucitone 199®) and 3 resilient liners (COE-SOFT™, GC RELINE™ and SOFRELINER TOUGH TOUGH®) were incubated in denture cleansers (Polident® an...

متن کامل

Influence of composition and powder/liquid ratio on setting characteristics and mechanical properties of autopolymerized hard direct denture reline resins

Reline of ill-fitting complete and removable partial dentures enhances their stability and retention by improving the adaptation between the denture intaglio surface and denture-bearing mucosa1). In clinical situations, that reline procedure is usually performed using a direct (chair-side reline system) rather than indirect (laboratory-processed reline system) method, because the former is more...

متن کامل

Effects of Soft Denture Liners on L929 Fibroblasts, HaCaT Keratinocytes, and RAW 264.7 Macrophages

The effects of six soft liners (Ufi Gel P (UG), Sofreliner S (SR), Durabase Soft (D), Trusoft (T), Coe Comfort (CC), and Softone (ST)) on L929, HaCat, and RAW 264.7 cells were investigated. Eluates (24 and 48 h) from the materials were applied on the cells and the viability, type of cell death, and morphology were evaluated. Cells were also seeded on the specimens' surfaces (direct contact) and...

متن کامل

A comparative evaluation of effect on water sorption and solubility of a temporary soft denture liner material when stored either in distilled water, 5.25% sodium hypochlorite or artificial saliva: An in vitro study

INTRODUCTION Soft denture liners have a key role in modern removable prosthodontics since they restore health to inflamed and abused mucosa by redistribution of forces transmitted to the edentulous ridges. The most common problems encountered using soft denture liners are water sorption and solubility when in contact with saliva or storage media. These problems are associated with swelling, dis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2014