Statistical Analysis on Functional and Radiographic Results after Use of Locked Volar Plate for Fractures of the Distal Radius

نویسندگان

  • Daniel Gonçalves Machado
  • Sergio Auto da Cruz Cerqueira
  • Rodrigo Ribeiro Pinho Rodarte
  • Carlos Alberto de Souza Araújo Netto
  • Marcelo Bezerra de Mathias
چکیده

OBJECTIVES To evaluate the functional results from using a fixed-angle locked volar plate for treating fractures of the distal extremity of the radius, using the DASH (disorders of the arm, shoulder and hand) questionnaire and its radiographic correlation with the Lidström classification. METHODS Thirty patients with unstable fractures of the distal extremity of the radius were evaluated after they had undergone a surgical procedure consisting of open reduction and internal fixation using a fixed-angle locked volar plate, at the Military Police Central Hospital of Rio de Janeiro between 2008 and 2009. The results were assessed based on range of motion, DASH protocol scores and radiographies with the Lidström classification. RESULTS The mean age of the patients in the study was 51 years. The mean DASH score was 11.9 points. It was observed that the radiographic findings did not influence the DASH score. It was found that flexion, pronation, supination and radial deviation correlated with the DASH score. CONCLUSIONS The study showed that subjective functional outcomes using the DASH protocol, obtained from using a locked volar plate to treat fractures of the distal extremity of the radius, are influenced by the range of motion, and especially by the flexion, supination, pronation and radial deviation of the wrist after surgery. There is no correlation between the radiological parameters of either the normal or the operated radius, and the subjective functional outcomes assessed using the DASH protocol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year

BACKGROUND AND PURPOSE Promising results have been reported after volar locked plating of unstable dorsally displaced distal radius fractures. We investigated whether volar locked plating results in better patient-perceived, objective functional and radiographic outcomes compared to the less invasive external fixation. PATIENTS AND METHODS 63 patients under 70 years of age, with an unstable e...

متن کامل

Dorsally displaced extra-articular distal radius fractures fixation: Dorsal IM nailing versus volar plating. A randomized controlled trial.

INTRODUCTION Fractures of the distal radius are very common and mainly occur in the elderly. There has been an increasing use of locked volar plate fixations which report satisfactory results. However, some authors advocate the use of nail fixation. HYPOTHESIS The aim of this study is to compare dorsal nail plate versus locked volar plate fixation in the treatment of distal radius fractures w...

متن کامل

Surgical Treatment of Distal Radius Fractures with a Volar Locked Plate: Correlation of Clinical and Radiographic Results.

OBJECTIVES To analyze and correlate the clinical and radiographic results from patients with distal radius fractures who underwent surgical treatment with a fixed-angle volar locked plate. METHODS Sixty-four patients with distal radius fractures were evaluated. They all underwent surgical treatment with a volar locked plate for the distal radius, with a minimum of six months of postoperative ...

متن کامل

Short-term Results of Using Injectable Bone Cement Technique in the Treatment of Unstable Distal Radius Fractures

Background & Aims: Treatment of osteoporotic distal radius fracture with metaphyseal defect is often complicated by secondary displacement, because of posterior cortex comminution. The aim of this study was to investigate functional outcomes and advantages of injection of bone cement in stabilizing and maintaining this fracture reduction. Methods: This prospective study was performed on 20 ...

متن کامل

Use of Volar Locking Plate Versus Intramedullary Nailing for Fixation of Distal Radius Fractures: A Retrospective Analysis of Clinical and Radiographic Outcomes

BACKGROUND The objective of this study was to evaluate clinical and radiographic outcomes of volar plate versus intramedullary nailing for fixation of distal radius fractures. MATERIAL AND METHODS This retrospective study included 64 patients with extra-articular and simple intra-articular fractures of the distal radius who underwent intramedullary fixation using volar locking plate (n=35, mean...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 47  شماره 

صفحات  -

تاریخ انتشار 2012