Characteristics associated with requested and required accelerometer wear in children

نویسندگان

  • Sian L Wells
  • Ruth R Kipping
  • Russell Jago
  • Judith Brown
  • Daniel Hucker
  • Ali Blackett
  • Debbie A Lawlor
چکیده

OBJECTIVE To investigate characteristics associated with wearing an accelerometer for the required and requested time among 8-year-old to 10-year-old children. DESIGN Cross-sectional. SETTING 60 Bristol and North Somerset primary schools taking part in the 'Active for Life Year 5' randomised controlled trial (RCT) in 2011. PARTICIPANTS 2048 children, aged 8-10 years, invited to wear an accelerometer for 5 days of recording. PRIMARY OUTCOME MEASURE Numbers meeting required wear-time for inclusion in main RCT analysis (≥8 h/day ≥3 days) and numbers meeting requested wear-time (≥8 h/day for all 5 days). RESULTS 817 (40%) of the children wore the accelerometer for the requested time and 1629 (80%) for the required time. In adjusted multivariable analyses the odds of wearing the accelerometer for the required time were greater in females as compared with males (OR 1.76 (1.42-2.18)), those with higher scores for reporting their mother restricted time on sedentary behaviours (1.26 (1.04-1.52) per increase of 1 on a 1-4 scale) and in children from schools with larger year group sizes (1.01 (1.00-1.02) per additional child). Living in a neighbourhood with higher levels of deprivation (0.49 (0.33-0.72) comparing highest to lowest third of the deprivation score) or reporting higher levels of weekday outdoor play (0.97 (0.94, 1.00) per 30 min more) were associated with reduced odds of meeting required time. Results were essentially the same for requested wear-time. Other characteristics, including child body mass index, were not associated with required or requested wear-time. CONCLUSIONS Only 40% of children wore the accelerometer for the requested time but 80% fulfilled the required criteria to be included in the main study analyses. Knowing which characteristics are associated with accelerometer wear could help target interventions to increase wear-time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving wear time compliance with a 24-hour waist-worn accelerometer protocol in the International Study of Childhood Obesity, Lifestyle and the Environment (ISCOLE)

BACKGROUND We compared 24-hour waist-worn accelerometer wear time characteristics of 9-11 year old children in the International Study of Childhood Obesity, Lifestyle and the Environment (ISCOLE) to similarly aged U.S. children providing waking-hours waist-worn accelerometer data in the 2003-2006 National Health and Nutrition Examination Survey (NHANES). METHODS Valid cases were defined as ha...

متن کامل

Quality Control Methods in Accelerometer Data Processing: Defining Minimum Wear Time

BACKGROUND When using accelerometers to measure physical activity, researchers need to determine whether subjects have worn their device for a sufficient period to be included in analyses. We propose a minimum wear criterion using population-based accelerometer data, and explore the influence of gender and the purposeful inclusion of children with weekend data on reliability. METHODS Accelero...

متن کامل

Classification of accelerometer wear and non-wear events in seconds for monitoring free-living physical activity

OBJECTIVE To classify wear and non-wear time of accelerometer data for accurately quantifying physical activity in public health or population level research. DESIGN A bi-moving-window-based approach was used to combine acceleration and skin temperature data to identify wear and non-wear time events in triaxial accelerometer data that monitor physical activity. SETTING Local residents in Sw...

متن کامل

From Sedentary Time to Sedentary Patterns: Accelerometer Data Reduction Decisions in Youth

AIM This study aims to establish evidence-based accelerometer data reduction criteria to accurately assess total sedentary time and sedentary patterns in children. METHODS Participants (n = 1057 European children; 9-13 yrs) were invited to wear an accelerometer for at least 6 consecutive days. We explored 1) non-wear time criteria; 2) minimum daily valid wear time; 3) differences between week...

متن کامل

Accelerometry and physical activity questionnaires - a systematic review

BACKGROUND The aim of this study is to review accelerometer wear methods and correlations between accelerometry and physical activity questionnaire data, depending on participant characteristics. METHODS We included 57 articles about physical activity measurement by accelerometry and questionnaires. Criteria were to have at least 100 participants of at least 18 years of age with manuscripts a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2013