Verification of a Method for Sizing All Proprietary Single Chamber Treatment Devices with Settling as a Unit Process

نویسنده

  • Roger Bannerman
چکیده

Methods for sizing single chamber tanks to remove different amounts of total suspended solids (TSS) have been available for some time. One method found in the literature uses the concept of upflow velocity (v) or the critical settling velocity of a particle in a tank to determine what size particles will be removed in the tank. The critical settling velocity depends on the relationship between discharge rate from the tank (Q) and the surface area of the tank (A) as described in the equation v = Q/A. One of the urban runoff models using this relationship to determine the efficiency of settling devices is the Source Loading and Management Model (WinSLAMM). The purpose of this paper is to verify the upflow velocity concept as it is used in WinSLAMM. The model is tested with the results from monitoring the effectiveness of two proprietary stormwater treatment practices – the Stormceptor and Vortechs System. Both of these practices rely on settling as the mechanism for removing solids from the flow stream. The model is tested using the site specific characteristics, such as rainfall, dimensions of each practice, and the average particle size distributions. The reductions of TSS estimated by the model closely matched the measured sum of the loads values (SOL). The TSS measured SOL value for the Stormceptor and the Vortechs is 5 and 19 percent respectively, while the model predicted values of 12 and 19 percent. The model results do not match the efficiencies of the individual storms as well as a group of storms. Information is not provided to the model on the variation in particle size distribution between storms, the variability in influent concentrations, and the identity of storms with re-suspension of trapped sediments. Results of this verification effort indicate the upflow velocity method should provide a reasonable estimate of the longterm TSS reductions expected for single chamber proprietary treatment practice that use settling as the primary unit process.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo dose verification using using an amorphous silicon flat panel-type imager (a-Si EPIDs)

Introduction: Electronic portal imaging devices (EPIDs) could be used to dose verification of radiotherapy treatment plans. In vivo dose verification is performed to reduce differences found between dose delivered to the patient and the prescribed dose. The aim of this study was to perform a fast and efficient technique for the verification of delivered dose to the patient usin...

متن کامل

Optimal Placement and Sizing of TCSC & SVC for Improvement Power System Operation using Crow Search Algorithm

Abstract: The need for more efficient power systems has prompted the use of a new technologies includes Flexible AC transmission system (FACTS) devices. FACTS devices provides new opportunity for controlling the line power flow and minimizing losses while maintaining the bus voltages within a permissible limit. In this thesis a new method is proposed for optimal placement and sizing of Thyristo...

متن کامل

Pretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)

Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...

متن کامل

A SAIWD-Based Approach for Simultaneous Reconfiguration and Optimal Siting and Sizing of Wind Turbines and DVR units in Distribution Systems

In this paper, a combination of simulated annealing (SA) and intelligent water drops (IWD) algorithm is used to solve the nonlinear/complex problem of simultaneous reconfiguration with optimal allocation (size and location) of wind turbine (WT) as a distributed generation (DG) and dynamic voltage restorer (DVR) as a distributed flexible AC transmission systems (DFACT) unit in a distribution sys...

متن کامل

The evaluation of minimum detectable phantom thickness change using a scanning liquid filled ion chamber EPID dose response

 ABSTRACTBackground: Although Electronic Portal imaging Devices (EPIDs) have originally developed for positioning verification, they can also be used for dosimetric purposes. In the current work, the dose response of minimum detectable thickness of a Scanning Liquid filled Ion Chamber EPID, SLIC-EPID, and the variation of transmitted dose with the shift of inhomogeneity inside of phantom was al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009