Measurement and Comparison of Organic Compound Concentrations in Plasma, Whole Blood, and Dried Blood Spot Samples
نویسندگان
چکیده
The preferred sampling medium for measuring human exposures of persistent organic compounds (POPs) is blood, and relevant sample types include whole blood, plasma, and dried blood spots (DBS). Because information regarding the performance and comparability of measurements across these sample types is limited, it is difficult to compare across studies. This study evaluates the performance of POP measurements in plasma, whole blood and DBS, and presents the distribution coefficients needed to convert concentrations among the three sample types. Blood samples were collected from adult volunteers, along with demographic and smoking information, and analyzed by GC/MS for organochlorine pesticides (OCPs), chlorinated hydrocarbons (CHCs), polychlorinated biphenyls (PCBs), and brominated diphenyl ethers (PBDEs). Regression models were used to evaluate the relationships between the sample types and possible effects of personal covariates. Distribution coefficients also were calculated using physically-based models. Across all compounds, concentrations in plasma were consistently the highest; concentrations in whole blood and DBS samples were comparable. Distribution coefficients for plasma to whole blood concentrations ranged from 1.74 to 2.26 for pesticides/CHCs, averaged 1.69 ± 0.06 for the PCBs, and averaged 1.65 ± 0.03 for the PBDEs. Regression models closely fit most chemicals (R (2) > 0.80), and whole blood and DBS samples generally showed very good agreement. Distribution coefficients estimated using biologically-based models were near one and did not explain the observed distribution. Among the study population, median concentrations of several pesticides/CHCs and PBDEs exceeded levels reported in the 2007-2008 National Health and Nutrition Examination Survey, while levels of other OCPs and PBDEs were comparable or lower. Race and smoking status appeared to slightly affect plasma/blood concentration ratios for several POPs. The experimentally-determined distribution coefficients can be used to compare POP exposures across studies using different types of blood-based matrices.
منابع مشابه
Use of dried blood spots for the determination of plasma concentrations of nevirapine and efavirenz.
OBJECTIVES Plasma concentrations are frequently used for therapeutic drug monitoring of antiretroviral drugs. Dried blood spot sampling offers a patient-friendly and easy alternative to plasma sampling. However, dried blood spot concentrations are not necessarily equal to plasma concentrations and therefore the objective of this work was to establish the relationship between nevirapine and efav...
متن کاملMeasurement of in vivo therapeutic mAb concentrations: comparison of conventional serum/plasma collection and analysis to dried blood spot sampling.
BACKGROUND Development of an alternative sampling method that uses small amounts of whole blood, such as dried blood spots (DBS), would be an advance in the quantitative assay field. Previously, we assessed the ability to quantitate therapeutic monoclonal antibodies present in DBS compared with a typical serum sample-based method, and concluded that measurements in DBS were reproducible and yie...
متن کاملMeasurement of glycated hemoglobin A1c from dried blood by turbidimetric immunoassay.
BACKGROUND Glycated hemoglobin A1c (A1C) is an important marker in the diagnosis and treatment of diabetes. Dried blood measurement of A1C is useful in large scale epidemiological evaluation of A1C, especially to assess the impact of intervention programs. The possibility of using dried blood for measurement of A1C by the immunoturbidimetric method was explored in the present study. METHOD Bl...
متن کاملThe Comparison of Acetic Acid and Strontium Chloride Procedures for Extraction of Hemin
Abstract Background and objectives: Hemin is a porphyrin compound derived from hemoglobin, the precursor of other porphyrin hemoglobin derivatives and the raw material of Hematin. Since hemin is widely used in medicine, we decided primarily to synthesize this substance in Laboratory and to determine the best way of hemin extraction from untransfused and expired blood units. Materials and Method...
متن کاملDetection of mucopolysaccharidosis type II by measurement of iduronate-2-sulfatase in dried blood spots and plasma samples.
BACKGROUND Mucopolysaccharidosis type II (MPS II) is a lysosomal storage disorder related to a deficiency in the enzyme iduronate-2-sulfatase (IDS). Clinical trials of enzyme replacement therapy are in progress, but effective treatment will require screening assays to enable early detection and diagnosis of MPS II. Our study evaluated the diagnostic accuracy of IDS protein and enzyme activity m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Frontiers in genetics
دوره 7 شماره
صفحات -
تاریخ انتشار 2016