Redefining Knee Balance in a Medially Stabilized Prosthesis: An In-Vitro Study
نویسندگان
چکیده
Background To date, there is still no consensus on what soft tissues must be preserved and what structures can be safely released during total knee arthroplasty (TKA) with a medially stabilized implant. Objective The aim of this study was to analyze the effect of a progressive selective release of the medial and lateral soft tissues in a knee implanted with a medially stabilized prosthesis. Method Six cadaveric fresh-frozen full leg specimens were tested. In each case, kinematic pattern and mediolateral laxity were measured in three stages: firstly, prior to implantation; secondly, after the implantation of the trial components, but before any soft tissue release; and thirdly, progressively as soft tissue was released with the trial implant in place. The incremental impact of each selective release on knee balance was then analyzed. Results In all cases sagittal stability was not affected by the progressive release of the lateral soft tissue envelope. It was possible to perform progressive lateral release provided the anterior one-third of the iliotibial band (ITB) remained intact. Progressive medial release could be performed on the medial side provided the anterior fibers of the superficial medial collateral ligament (sMCL) remained intact. Conclusion The medially conforming implant remains stable provided the anterior fibers of sMCL and the anterior fibers of the ITB remain intact. The implant's sagittal stability is mainly dependent on its medial ball-in-socket design.
منابع مشابه
Mobile-bearing Total Knee Prostheses Reduce Axial Rotational Constraint Torque
INTRODUCTION: The current study compared in-vitro tibiofemoral axial rotational constraint between 2 posterior stabilized mobile-bearing knee prosthesis and their fixed-bearing counterparts. It was demonstrated that both mobile-bearing knees induced significantly less constraint torque compared to their fixed-bearing counterparts. Highly-constrained design of the fixed-bearing knees substantial...
متن کاملInvestigating the Impact of Knee Prosthesis in Patients’ Body on Radiation Dose Distribution: A Monte Carlo Approach
Introduction: Metal prostheses in patients affect the radiotherapy dose distribution. Metal prostheses with high density and atomic number cause major changes in scattering and attenuation of radiation. The present study aims to assess the impact of metal knee prosthesis with various dimensions and materials on radiotherapy dose distribution. Material and Methods: In this research, the Varian L...
متن کاملPolyethylene wear particles in synovial fluid after total knee arthroplasty.
The aims of the current study were to examine polyethylene particles in synovial fluid at an early stage, and to compare a newly introduced medial pivot total knee prosthesis with an established posterior-stabilized total knee prosthesis. Synovial fluid was obtained 1 year after knee arthroplasty from 17 patients with well-functioning prostheses (22 knees, 11 posterior-stabilized prostheses and...
متن کاملRe: Comparison of mobile-bearing and fixed-bearing total knee arthroplasty: a prospective randomized study.
The purpose of this prospective randomized study was to compare the postoperative recovery and early results of 2 groups of patients undergoing total knee arthroplasty: 107 patients received an established fixed-bearing posterior-stabilized prosthesis (Legacy Posterior Stabilized [LPS]), and 103 patients the meniscal-bearing prosthesis (Meniscal Bearing Knee [MBK]). Surgical procedures were the...
متن کاملDynamic in vitro measurement of patellar movement after total knee arthroplasty: an in vitro study
BACKGROUND Changing the kinematic behaviour of patellar movement could be one of the reasons for anterior knee pain after implantation of a total knee arthroplasty (TKA). The aim of the current study was to measure the potential influence on patellar kinematics of patellar resurfacing during TKA. METHODS Patellar movement before and after TKA with and without patellar resurfacing was measured...
متن کامل