Differences in Central Corneal Thickness between Spectral Domain-Optical Coherence Tomography and Ultrasound Pachymetry in Patients with Dry Eye Disease
نویسندگان
چکیده
Purpose. To compare central corneal thickness (CCT) values via Spectral Domain-Optical Coherence Tomography (SD-OCT) and ultrasonic pachymetry in patients with severe dry eye disease (DED) to determine the level of agreement between these 2 methods. Methods. The paired samples t-test was used to compare CCT values in severe DED patients. Matching analysis between methods was performed using intraclass correlation coefficient (ICC). Intrasession reliability of the measurement methods was calculated via the concordance correlation coefficient (CCC), variation equivalent, and Pearson's correlation coefficient. The Bland-Altman procedure was used to graphically represent the differences between CCT values. Results. The study included 56 eyes of 24 female and 4 male patients. Mean age of the patients was 50.9 ± 11.3 years. Mean CCT via Cirrus SD-OCT was 523.82 ± 30.98 μm versus 530.050 ± 31.85 μm via ultrasonic pachymetry (paired samples t-test, P < 0.001). The Bland-Altman plot showed good agreement between the examiners. The ICC for repeatability was 0.974. The CCC between the 2 methods' CCT values was 0.973. The variation equivalent was 0.976 and Pearson's correlation coefficient was 99.3%, which also indicated high correlation between the 2 methods' measurements. Conclusions. The present findings show that in patients with severe DED Cirrus SD-OCT provides reliable intraobserver CCT values.
منابع مشابه
Intraoperative Pachymetry Using Spectral-Domain Optical Coherence Tomography during Accelerated Corneal Collagen Crosslinking
PURPOSE To evaluate the role of spectral-domain optical coherence tomography (SDOCT) to measure corneal thickness during accelerated corneal crosslinking (CXL). METHODS Intraoperative pachymetry was performed using SDOCT and ultrasound pachymetry (USP) in 6 eyes of 6 patients with keratoconus. Pachymetry readings were obtained at baseline, after epithelium removal and after 30 minutes of ribo...
متن کاملComparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements
BACKGROUND The purpose of this study was to compare and correlate central corneal thickness in healthy, nonoperated eyes with three advanced anterior-segment imaging systems: a high-resolution Scheimpflug tomography camera (Oculyzer II), a spectral-domain anterior-segment optical coherence tomography (AS-OCT) system, and a high-frequency ultrasound biomicroscopy (HF-UBM) system. METHODS Fifty...
متن کاملRetinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography
Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...
متن کاملAccuracy of optical coherence tomography (OCT) in pachymetry for glaucoma patients
BACKGROUND Central corneal thickness (CCT) measurement has become an important test in the diagnosis and management of glaucoma. Currently, ultrasound corneal thickness measurement (pachymetry) is the most frequently used clinical technique and the gold standard to assess CCT. Newer instruments are currently available including the optical coherence tomography (OCT) instrument. The aim of the p...
متن کاملCentral corneal thickness measurements with optical coherence tomography and ultrasound pachymetry in healthy subjects and in patients after photorefractive keratectomy.
PURPOSE To compare central corneal thickness measurements made using two different methods, optical coherence tomography (OCT) and ultrasound pachymetry, applied both in normal eyes and in eyes on which photorefractive keratectomy (PRK) had been performed. A second objective was to assess the intrasession variability of OCT measurements. METHODS In this prospective study, central corneal thic...