Bone structure and density via HR-pQCT in 60d bed-rest, 2-years recovery with and without countermeasures.

نویسندگان

  • D L Belavy
  • G Beller
  • Z Ritter
  • D Felsenberg
چکیده

We examined the effects of bed-rest, recovery and exercise countermeasures on bone density and structure at the distal tibia and radius as measured via high-resolution peripheral computed tomography. 24 subjects underwent 60-days of head-down tilt bed-rest and performed either resistive vibration exercise (RVE; n = 7), resistive exercise only (RE; n = 8) or no exercise (n = 9; 2nd Berlin BedRest Study; BBR2-2). Measurements were performed regularly during and up to 2-years after 60d bed-rest. At the distal tibia marked reductions in cortical area, cortical thickness and bone density but increases in periosteal perimeter and trabecular area were seen (p all<0.001). Recovery of most parameters occurred within 180d after bed-rest. At the distal radius, persistent increases in cortical area, cortical thickness, cortical density and total density and decreases in trabecular area were seen (p all ≤ 0.005). A significant effect of RVE (p = 0.003), but not RE, was seen on cortical area at the distal tibia, with few effects of the countermeasures observed on the remaining parameters. The current study represents the first implementation of high-resolution peripheral computed tomography in bed-rest in male subjects and helps to understand the patterns of bone remodeling due to bed-rest and recovery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomical sector analysis of load-bearing tibial bone structure during 90-day bed rest and 1-year recovery.

The aim of this study was to investigate whether the bone response to long bed rest-related immobility and during subsequent recovery differed at anatomically different sectors of tibial epiphysis and diaphysis. For this study, peripheral quantitative tomographic (pQCT) scans obtained from a previous 90-day 'Long Term Bed Rest' intervention were preprocessed with a new method based on statistic...

متن کامل

Least significant changes and monitoring time intervals for high-resolution pQCT-derived bone outcomes in postmenopausal women

BACKGROUND Least Significant Change (LSC) assists in determining whether observed bone change is beyond measurement precision. Monitoring Time Interval (MTI) estimates time required to reliably detect skeletal changes. MTIs have not been defined for bone outcomes provided by high resolution peripheral quantitative computed tomography (HR-pQCT). The purpose of this study was to determine the LSC...

متن کامل

Bone microarchitecture in hemodialysis patients assessed by HR-pQCT.

BACKGROUND AND OBJECTIVES Dialysis patients are at high risk for low-trauma bone fracture. Bone density measurements using dual-energy x-ray absorptiometry (DXA) do not reliably differentiate between patients with and without fractures. The aim of this study was to identify differences in bone microarchitecture between patients with and without a history of fracture using high-resolution periph...

متن کامل

Skeletal effects of long-duration head-down bed rest.

INTRODUCTION Skeletal unloading during spaceflight causes regional loss of bone mineral density (BMD), primarily in the spine and lower body regions. This loss of skeletal mass could adversely affect crew health during and after spaceflight and jeopardize mission success. Bed rest has long been used as a spaceflight analog to study the effects of disuse on many body systems, including the skele...

متن کامل

Effect of a Cast on Short-Term Reproducibility and Bone Parameters Obtained from HR-pQCT Measurements at the Distal End of the Radius.

BACKGROUND High-resolution peripheral quantitative computed tomography (HR-pQCT) is a promising tool to assess the fracture-healing process at the microscale in vivo. Since casts are often used during fracture treatment, they might affect the assessment of bone density, microarchitectural, and biomechanical parameters and the short-term reproducibility of those parameters, e.g., as a result of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of musculoskeletal & neuronal interactions

دوره 11 3  شماره 

صفحات  -

تاریخ انتشار 2011