Effects of 1:1, 1:2 or 1:3 intra-aortic balloon counterpulsation/heart support on coronary haemodynamics and cardiac contractile efficiency in an animal model of myocardial ischaemia/reperfusion.

نویسندگان

  • Sandro Gelsomino
  • Attilio Renzulli
  • Antonino S Rubino
  • Salvatore Mario Romano
  • Fabiana Lucà
  • Serafina Valente
  • Gian Franco Gensini
  • Roberto Lorusso
چکیده

OBJECTIVES The effects of operational modes of intra-aortic balloon pumping (IABP) on coronary haemodynamics and oxygen delivery/demand ratio are unknown and were investigated in an experimental model of myocardial ischaemia reperfusion. METHODS Healthy swine (n = 24) underwent 120-minute ligation of the left anterior descending coronary artery followed by 24 h of reperfusion and were randomly assigned to have IABP 1:1 (n = 6), IABP 1:2 (n = 6), IABP 1:3 (n = 6) in the descending aorta or to no IABP implantation (n = 6) 5 min after the onset of reperfusion. Systolic (CBF(Sys)) and diastolic (CBF(Dia)) coronary blood flow, systolic (CR(Sys)) and diastolic (CR(Dia)) coronary resistances and endocardial viability ratio (EVR), as an expression of the oxygen delivery/demand ratio, were measured at 30 min, 1, 6, 12 and 24 h after coronary reperfusion, respectively. RESULTS IABP at the 1:1 operational mode significantly increased CBF(Dia) and EVR, and reduced CR(Dia) throughout the experiment. Contrastingly, IABP at 1:3 mode resulted in a significant reduction in CBF(Dia), in a steady increase in CR(Dia), in a steady reduction in O(2) delivery and a constant increase in O(2) demand over time. IABP at the 1:2 mode had no overall effect on assessed parameters. CONCLUSIONS IABP at the 1:1 mode enhanced coronary haemodynamics and cardiac contractile efficiency in an acute animal model of coronary ischaemia/reperfusion. On the contrary, IABP support set at the 1:2 or 1:3 modes failed to provide benefit. Progressive reduction in balloon inflation with a 1:1 mode instead of decreasing the heart/IABP operational ratio might represent a better IABP withdrawal protocol and is currently under investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of percutaneous coronary minimalist intervention in the management of acute ST-segment elevation myocardial infarction.

1. Smalling RW, Cassidy DB, Barrett R, et al. Improved regional myocardial blood flow, left ventricular unloading, and infarct salvage using an axial-flow, transvalvular left ventricular assist device. A comparison with intra-aortic balloon counterpulsation and reperfusion alone in a canine infarction model. Circulation 1992;85:1152–9. 2. Henriques JP, Remmelink M, Baan J Jr., et al. Safety and...

متن کامل

The effect of intra-aortic balloon counterpulsation on left ventricular functional recovery early after acute myocardial infarction: a randomized experimental magnetic resonance imaging study.

AIMS We sought to determine whether intra-aortic balloon pump (IABP) counterpulsation improves the recovery of left ventricular (LV) systolic function after reperfused acute myocardial infarction (AMI). METHODS AND RESULTS Fourteen dogs underwent 90-min coronary artery occlusion followed by reperfusion. Seven animals were randomized to IABP counterpulsation immediately after reperfusion. Tagg...

متن کامل

Effects of intra-aortic balloon counterpulsation on cardiac performance, oxygen consumption, and coronary blood flow in dogs.

The effect of intra-aortic counterpulsation (IACP) with a balloon upon myocardial oxygen consumption (MVo2), coronaiy blood flow (TCF), and left ventricular performance was studied in 23 anesthetized canine right heart bypass preparations at constant heart rate and cardiac output. In nonhypotensive, nonTCF-limited preparations, IACP produced a fall in left ventricular peak systolic pressure (LV...

متن کامل

The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery

Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In thi...

متن کامل

Randomized comparison of intra-aortic balloon support with a percutaneous left ventricular assist device in patients with revascularized acute myocardial infarction complicated by cardiogenic shock.

AIMS Mortality in cardiogenic shock (CS) following acute myocardial infarction (AMI) remains unacceptably high despite percutaneous coronary intervention (PCI) of the infarcted artery and use of intra-aortic balloon pump (IABP) counterpulsation. A newly developed percutaneous left ventricular assist device (VAD) (Tandem Heart, Cardiac Assist, Pittsburgh, PA, USA) with active circulatory support...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 42 2  شماره 

صفحات  -

تاریخ انتشار 2012