Pacing System Malfunction: Evaluation and Troubleshooting

نویسنده

  • Majid Haghjoo
چکیده

Currently, most of the time spent caring for the patients with permanent pacemaker will be concerned with evaluating the function of the previously implanted pacing system. Pacing system malfunction can be secondary to pacemaker circuitry failure or to lead dysfunction. Various tools are available to help evaluation of the pacing system malfunction, including physical examination, standard 12-lead ECG, ambulatory ECG monitoring, stored telemetry data, chest x-ray, and fluoroscopy. This chapter will discuss the differential diagnosis, evaluation, and management of the common malfunctions encountered in the single-chamber, dual-chamber, and biventricular pacing system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Troubleshooting with Simultaneous Models

The goal of decision-theoretic troubleshooting is to find a sequence of actions that minimizes the expected cost of repair of a device. If the device is complex then it is convenient to create several Bayesian Networks, each designed to solve a particular problem. At the beginning of a troubleshooting process, it is often necessary to help the user to select the proper model. Complications aris...

متن کامل

Incidence of lead system malfunction detected during implantable defibrillator generator replacement.

Implantable cardioverter-defibrillator (ICD) generator replacement due to a depleted battery is a frequently performed procedure. The frequency with which sensing and defibrillation system failures are identified during device replacement procedures has not been previously described. Therefore, the purpose of this study was to prospectively determine the frequency of lead system malfunction det...

متن کامل

Temporary epicardial pacing after cardiac surgery: a practical review. Part 2: Selection of epicardial pacing modes and troubleshooting.

The first part of this two-part review discussed the indications for various types of epicardial pacing systems and an overview of the routine care of a pacemaker-dependent patient. Dual chamber temporary pulse generators now feature many of the refinements developed initially for use in permanent pacemakers. Few of these are utilised in the immediate postoperative period, often solely due to l...

متن کامل

Novel Technique of Dual Chamber Pacing Through Mini-thoracotomy and Transatrial Endocardial Active Fixation Lead Insertion for Epicardial Pacing Lead Malfunction

Epicardial pacing lead fixation is employed in patients with cavopulmonary anastamosis (Glenn shunts) when they need permanent pacing. Epicardial pacing in these patients may malfunction due to high pacing thresholds or diaphragmatic pacing. A novel technique of transatrial insertion of two endocardial screw-in pacing leads through right anterolateral minithoracotomy could achieve synchronous a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -