Ultrasound attenuation measurements using a reference phantom with sound speed mismatch.

نویسندگان

  • Kibo Nam
  • Ivan M Rosado-Mendez
  • Nicholas C Rubert
  • Ernest L Madsen
  • James A Zagzebski
  • Timothy J Hall
چکیده

Ultrasonic attenuation may be measured accurately with clinical systems and array transducers by using reference phantom methods (RPM) to account for diffraction and other system dependencies on echo signals. Assumptions with the RPM are that the speeds of sound in the sample (c(sam)) and in the reference medium (c(ref)) are the same and that they match the speed assumed in the system beamformer (c(bf)). This work assesses the accuracy of attenuation measurements by the RPM when these assumptions are not met. Attenuation was measured for two homogeneous phantoms, one with a speed of sound of 1500 m/s and the other with a sound speed of 1580 m/s. Both have an attenuation coefficient approximately equal to that of the reference, in which the speed of sound is 1540 m/s. Echo signals from the samples and the reference were acquired from a Siemens S2000 scanner with a 9L4 linear array transducer. Separate acquisitions were obtained with c(bf) at its default value of 1540 m/s and when it was set at values matching the speeds of sound of the phantoms. Simulations were also performed using conditions matching those of the experiment. RPM-measured attenuation coefficients exhibited spatially-dependent biases when c(sam) differed from c(df) and c(ref). Mean errors of 19% were seen for simulated data, with the maximum errors in attenuation measurements occurring for regions of interest near the transmit focus. Biases were minimized (mean error with simulated data was 5.6%) using c(bf) that matched c(sam) and assuring that power spectra used for attenuation computations in the sample are from precisely the same depth as those from the reference. Setting the transmit focus well beyond the depth range used to compute attenuation values minimized the bias.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation study of effects of speed of sound and attenuation on ultrasound lateral resolution.

Experiments have shown that the lateral profile of a point target measured with a clinical ultrasound scanner is wider when the target is embedded in a urethane phantom than when it is in a traditional gel phantom. The behavior has been attributed to the low speed of sound in the urethane material, with the possibility that some of the broadening is caused by increased attenuation in this mater...

متن کامل

Theoretical and phantom based investigation of the impact of sound speed and backscatter variations on attenuation slope estimation.

Quantitative ultrasound features such as the attenuation slope, sound speed and scatterer size, have been utilized to evaluate pathological variations in soft tissues such as the liver and breast. However, the impact of variations in the sound speed and backscatter due to underlying fat content or fibrotic changes, on the attenuation slope has not been addressed. Both numerical and acoustically...

متن کامل

The Ability of Ultrasonic Characterization to Extract the Dose Distribution of MAGIC-f Polymer Gel

Background & Aims: Today, different imaging techniques have been studied in the reading of radiationsensitive polymer gels dosage. Due to limitations of imaging techniques such as magnetic resonance imaging (MRI) and computed tomography (CT), ultrasound techniques are proposed for dose-dependent parameter extraction. In this study, using MAGIC-f (methacrylic and ascorbic acid in gelatin initiat...

متن کامل

Properties of phantom tissuelike polymethylpentene in the frequency range 20-70 MHZ.

Quantitative ultrasound (QUS) has been used to characterize soft tissues at ordinary abdominal ultrasound frequencies (2 to 15 MHz) and is beginning application at high frequencies (20 to 70 MHz). For example, backscatter and attenuation coefficients can be estimated in vivo using a reference phantom. At high frequencies, it is crucial that reverberations do not compromise the measurements. Suc...

متن کامل

Evaluation of the impact of backscatter intensity variations on ultrasound attenuation estimation.

PURPOSE Quantitative ultrasound based approaches such as attenuation slope estimation can be used to determine underlying tissue properties and eventually used as a supplemental diagnostic technique to B-mode imaging. The authors investigate the impact of backscatter intensity and frequency dependence variations on the attenuation slope estimation accuracy. METHODS The authors compare three f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultrasonic imaging

دوره 33 4  شماره 

صفحات  -

تاریخ انتشار 2011