Detection of moving flow separation in pulsatile flow and the degree of stenosis by power of Doppler shift signals.

نویسندگان

  • T Tamura
  • A Fronek
چکیده

Power ratios were derived from the principle of ultrasonic Doppler velocimetry to determine a ratio of the volume of vortices to the total vessel volume under the ultrasonic beam. This ratio also equals the ratio of the cross-sectional area of vortices to the vessel lumen. In vitro pulsatile flow experiments were performed in a Reynolds number range of 1,230-4,320 with axisymmetric constrictions with area reductions of 55%, 65%, 70%, and 85% to model carotid stenosis. Flow separation downstream from the model stenoses was detected, and the power ratio fluctuated when vortices with the forward- and reverse-flow velocity components passed by the measurement position. The power ratio estimated the degree of stenosis within 10% of error. Ensemble average of the power ratio was computed to obtain the statistically averaged separated flow region. The moving flow reattachment point was revealed downstream from the 85% stenosis at a Reynolds number of 900.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Newtonian and Non-Newtonian Blood Flow Simulation after Arterial Stenosis- Steady State and Pulsatile Approaches

Arterial stenosis, for example Atherosclerosis, is one of the most serious forms of arterial disease in the formation of which hemodynamic factors play a significant role. In the present study, a 3-D rigid carotid artery with axisymmetric stenosis with 75% reduction in cross-sectional area is considered. Laminar blood flow is assumed to have both Newtonian and non-Newtonian behavior (generalize...

متن کامل

Effect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery

A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...

متن کامل

Numerical Study of Hemodynamic Wall Parameters on Pulsatile Flow through Arterial Stenosis

In this paper hemodynamic wall parameters which play an important role to diagnose arterial disease were studied and compared for three different rheology models (Newtonian, Power law and Quemada). Also because of the pulsatile behavior of blood flow the results were obtained for three Womersley numbers which represent the frequencies of the applied pulses. Results show that Quemada model alway...

متن کامل

I-46: Obstetrical Doppler

Accurate assessment of gestational age, fetal growth, and the detection of fetal and placental abnormalities are major benefits of sonography. Color Doppler can be used to assist in the identification of vascular architecture, detection of vascular pathology and visualization of blood flow changes associated with physiologic processes and disease states. The clinical applications of obstetrical...

متن کامل

An implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery

With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation research

دوره 67 1  شماره 

صفحات  -

تاریخ انتشار 1990