Laboratory-Measured MTF of IOLs and Clinical Performance.
نویسندگان
چکیده
We read with interest the article by Esteve-Taboada et al.1 The authors measured the modulation transfer function (MTF) of three intraocular lenses (IOLs) using a corneal eye model with zero spherical aberration using monochromatic light. This means that corneal higher order aberrations and chromatic aberration were not taken into account for the evaluation, even though it has been shown that spherical aberration and chromatic aberration have a significant effect on visual acuity and contrast sensitivity. The exclusion of spherical aberration in the measurement set-up follows the general guidelines of the International Organization of Standardization (ISO) for IOLs (ISO 11979-2:1999). The purpose of ISO standards, in general, is to ensure quality, safety, and efficiency, as well as to facilitate international trade.2 For this particular part of the standard, the primary purpose is to ensure manufacturing quality, and not in vivo performance.3 The current ISO standard provides the reader with a warning by stating that when it comes to MTF measurements “No inference should be made to performance in real eyes” (ISO 119792:2014, Clause C.2). In a previous commentary on a similar study by Artigas et al.,4 Norrby warned that the aberration-free ISO model eye is not valid for assessing aspherical lenses.3 The three lens designs in the study of Esteve-Taboada et al. are refractive/diffractive designs, which are known to affect chromatic aberrations. The TECNIS Symfony IOL is designed to correct chromatic aberration5 for all distances, whereas the trifocal lenses are expected to influence chromatic aberration for near and/or intermediate vision.6 Excluding chromatic aberration and spherical aberration in the measurement set-up has a significant influence on the measured values. To illustrate this effect, Figure 1 shows MTF measurements7 similar to those of Esteve-Taboada et al., but now using a model eye that includes corneal spherical aberration of 0.27 micrometers, and that also includes chromatic aberration by using white light and having suitable dispersive properties of the cornea and fluid medium in which the IOL is immersed. As such, the model eye represents the spherical aberration and chromatic aberration that is also found in an average human eye. The difference in MTF obtained in this eye model and the results obtained by Esteve-Taboada et al. is obvious, and cannot be explained by the slight difference in pupil size in both studies. The difference can only be explained by the fact that the measurement conditions for MTF in the chromatic eye model were more representative for the clinical situation. The authors provide far-reaching statements concerning the implications of their findings toward clinical behavior, even though the understanding of the correlation with clinical outcomes is still limited for metrics based on measurements in a model eye. It must be understood that whatever correlation there may be, it will depend greatly on how the lenses were measured. An optimal correlation can only be achieved if the measurement conditions for MTF are representative for the clinical situation.
منابع مشابه
Optical bench performance of AcrySof® IQ ReSTOR®, AT LISA® tri, and FineVision® intraocular lenses
PURPOSE To compare the resolution and optical quality of the ReSTOR(®) +3.0 D and ReSTOR +2.5 D multifocal intraocular lenses (IOLs) with the AT LISA(®) tri and FineVision(®) trifocal IOLs. METHODS Resolution, image quality, and photic phenomena were evaluated in the AcrySof(®) IQ ReSTOR +3.0 D and +2.5 D multifocal IOLs and compared with the AT LISA tri 839MP and FineVision Micro F12 trifoca...
متن کاملEffects of intraocular lenses with different diopters on chromatic aberrations in human eye models
BACKGROUND In this study, the effects of intraocular lenses (IOLs) with different diopters (D) on chromatic aberration were investigated in human eye models, and the influences of the central thickness of IOLs on chromatic aberration were compared. METHODS A Liou-Brennan-based IOL eye model was constructed using ZEMAX optical design software. Spherical IOLs with different diopters (AR40e, AMO...
متن کاملPerformance of presbyopia-correcting intraocular lenses in distance optical bench tests.
PURPOSE To compare the optical performance of 6 presbyopia-correcting intraocular lenses (IOLs) of different designs (accommodating or multifocal and aspheric or spheric). SETTING Alcon Laboratories, Inc., Fort Worth, Texas, USA. METHODS The optical performance of 6 IOLs were compared using modulation transfer function (MTF) and the United States Air Force 1951 Resolution Target (AFT) testi...
متن کاملOptical and material analysis of opacified hydrophilic intraocular lenses after explantation: a laboratory study
BACKGROUND The opacification of hydrophilic intraocular lenses (IOLs) is a very rare complication in terms of absolute numbers. We report on the analyses of opacified Euromaxx ALI313Y and ALI313 IOLs (Argonoptics, Germany) using light and scanning electron microscopy, X-ray spectroscopy and optical bench analysis. METHODS Opacified Euromaxx ALI313Y and ALI313 IOLs were explanted after patient...
متن کاملIn vitro optical quality measurements of three intraocular lens models having identical platform
BACKGROUND With recent advances in technology and introduction of new intraocular lens (IOL) models, surgeons today have the opportunity to choose from various optical designs, which can influence the postoperative quality of vision. In our laboratory study, we compared the optical quality of three different IOLs that use the identical platform and are produced by the same manufacturer. The stu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 32 3 شماره
صفحات -
تاریخ انتشار 2016