Coronary stents: In vitro aspects of an angiographic and ultrasound quantification with in vivo correlation.
نویسندگان
چکیده
BACKGROUND The validity of quantitative coronary angiography (QCA) after stent placement has been questioned because the optical density of a metallic stent, added to the density of a contrast-filled lumen, could affect border definition. METHODS AND RESULTS We deployed 3.0- and 4.0-mm Palmaz-Schatz, Wiktor, Multilink, NIR, and InStent stents in precision-cast phantoms. Central lumens of 2.0 mm were created. There was no difference between the "true" diameters of any stented lumen by both QCA and quantitative ultrasonic (QCU) measurement poststenting. QCA systematic error (SE) varied from 0.01 for the Wiktor stents to 0.14 mm for the Palmaz-Schatz stents; the random error (RE) was 0.03 to 0.14 mm. QCU SE varied from 0.05 to 0.11 mm, and RE ranged from 0.01 to 0.07 mm. At the next stage, 4.0-mm Wiktor and Palmaz-Schatz stents were deployed into the phantom lumens; 1.5-, 2.0-, 2.5- and 3.0-mm lumens were created inside the stents. QCA and QCU measurements of 1.5- to 2.5-mm residual lumens were overestimated by 0.1 to 0.3 mm. In the 3. 0-mm residual lumen within the Wiktor stent, QCA underestimated the luminal size by -0.1 mm. There was no QCA inaccuracy for a 3.0-mm lumen within the Palmaz-Schatz stent. In patients, in 25 stented segments in both the Palmaz-Schatz and Wiktor groups, there was no difference between QCA and QCU diameters. CONCLUSIONS QCU is sufficiently precise for the assessment of the coronary lumen after stenting. QCA can be used as an accurate method of poststent assessment, except when a very mild recurrence within a highly opaque stent is measured. In that instance, QCA may underestimate the luminal diameter.
منابع مشابه
Simulation of longitudinal stent deformation in a patient-specific coronary artery.
In percutaneous coronary intervention (PCI), stent malapposition is a common complication often leading to stent thrombosis (ST). More recently, it has also been associated with longitudinal stent deformation (LSD) normally occurring through contact of a post balloon catheter tip and the protruding malapposed stent struts. The aim of this study was to assess the longitudinal integrity of first ...
متن کاملSafety, Efficacy and Clinical Outcome of Direct Stent Implantation
Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...
متن کاملAssociation Between Left Anterior Descending Artery Length with Coronary Artery Dominance: An Angiographic Study
Introduction: Although left anterior descending (LAD) artery supplies a large portion of the myocardium, the amount of blood supply provided by LAD is depended on the length of the LAD. The aim of the current study was to evaluate the association between coronary artery dominance and LAD anatomic types in patients with normal epicardial coronary arteries. Methods:...
متن کاملBasic Investigation The Genesis Stent: A New Low-Profile Stent for Use in Infants, Children, and Adults With Congenital Heart Disease
Placement of intravascular stents that can reach adult size in infants and smaller children has been limited by the large profile and poor flexibility of currently available stents. In vitro and in vivo testing of the Genesis stent was performed to evaluate crimpability, predeployment flexibility, and radial strength. Comparisons were made to the Palmaz iliac and IntraStent (IS) LD stents. Nine...
متن کاملبررسی ذخیره آهن در بیماران تحت آنژیوگرافی عروق کرونر
Background: Epidemiological studies have suggested an association between higher body iron stores and coronary artery disease. It is believed that inflammation and oxidation are important mechanisms involved in the complex pathological process of atherogenesis. Free radical production is catalyzed and accelerated in the presence of iron. The determination of plasma ferritin levels is a convenie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 98 15 شماره
صفحات -