Effects of a distal protection device during primary stenting in patients with acute anterior myocardial infarction.

نویسندگان

  • Tomohiro Nakamura
  • Norifumi Kubo
  • Yuichi Seki
  • Nahoko Ikeda
  • Takeshi Ishida
  • Hiroshi Funayama
  • Shigemasa Hashimoto
  • Takanori Yasu
  • Mikihisa Fujii
  • Masanobu Kawakami
  • Muneyasu Saito
چکیده

BACKGROUND The angiographic no-reflow phenomenon is an adverse prognostic factor in patients with acute myocardial infarction (AMI). The aim of the present study was to evaluate the effects of an occlusive balloon type distal protection device (PercuSurge GuardWire: GW) during primary stenting in patients with anterior AMI. METHODS AND RESULTS The GW group included 42 patients treated by primary stenting with GW protection and the control group included 30 patients treated by primary stenting after thrombectomy without distal protection. Left ventricular (LV) function was measured and compared by left ventriculography obtained soon after percutaneous coronary intervention (PCI) and 3 weeks after onset. The corrected TIMI frame count values were lower in the GW group than in the control group (27.5+/-2.3 vs 35.1 +/-2.5, p=0.030). The number of patients with myocardial blush grade 3 after PCI was higher in the GW group than in the control group (45.7 vs 20.0%, p=0.029). Peak concentration of creatine kinase myocardial fraction was lower in the GW group than in the control group (326.6+/-41.5 vs 454.9+/-46.2 mg/dl, p=0.043). GW patients showed greater improvement at 3 weeks after PCI in terms of LV ejection fraction (+4.6+/-1.2 vs -1.1+/-1.5, p=0.004), LV end-systolic volume index (+0.5+/-2.4 vs +9.0+/-2.7, p=0.023), and regional wall motion abnormalities (-2.03+/-0.14 vs -2.51+/-0.14, p=0.018). CONCLUSION Primary stenting with GW protection can restore epicardial coronary flow and myocardial perfusion, and also preserve LV function in anterior AMI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adjuvant therapy of breast cancer in the elderly: does one size fit all?

6. de Feyter PJ. Percutaneous treatment of saphenous vein bypass graft obstructions: a continuing obstinate problem. 7. Bejarano J. Mechanical protection of cardiac microcirculation during percuta-neous coronary interevntion of saphenous vein grafts. Int J Cardiol. In press. 8. Baim DS, Wahr D, George B, et al. Randomized trial of a distal embolic protection device during percutaneous intervent...

متن کامل

Distal protection during primary coronary intervention can preserve the index of microcirculatory resistance in patients with acute anterior ST-segment elevation myocardial infarction.

BACKGROUND The objective of this study was to investigate whether a distal protection (DP) device can preserve the index of microcirculatory resistance (IMR) after primary percutaneous coronary intervention (PCI) in patients with anterior ST-segment elevation myocardial infarction (STEMI). METHODS AND RESULTS The study group of 36 consecutive patients with anterior STEMI were randomized into ...

متن کامل

Effect of Distal Protection Device on the Microvascular Integrity during Primary Stenting in Acute Myocardial Infarction: Distal Protection Device in Acute Myocardial Infarction

Background and Objectives:Phasic coronary flow velocity patterns and microvascular integrities are known to be prognostic factors in acute myocardial infarction (AMI). The use of a distal protection device during primary percutaneous coronary intervention (PCI) may preserve the microvascular integrity of the myocardium by preventing distal embolization of thrombotic materials. This study assess...

متن کامل

Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts.

BACKGROUND Stents provide effective treatment for stenotic saphenous venous aorto-coronary bypass grafts, but their placement carries a 20% incidence of procedure-related complications, which potentially are related to the distal embolization of atherosclerotic debris. We report the first multicenter randomized trial to evaluate use of a distal embolic protection device during stenting of such ...

متن کامل

Letter by Naggara et al regarding article, "Are distal protection devices 'protective' during carotid angioplasty and stenting?".

BACKGROUND AND PURPOSE To evaluate the periprocedural outcome after carotid artery stenting with embolic brain protection (EBP+) versus without embolic brain protection (EBP-). METHODS We retrospectively reviewed data from a prospective nonrandomized database of 357 patients who underwent carotid artery stenting in the neuroradiology division of our institution from 1999 to 2009. One hundred ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 68 8  شماره 

صفحات  -

تاریخ انتشار 2004