b matrix errors in echo planar diffusion tensor imaging

نویسندگان

  • Saïd Boujraf
  • Robert Luypaert
  • Michel Osteaux
چکیده

Diffusion-weighted magnetic resonance imaging (DW-MRI) is a recognized tool for early detection of infarction of the human brain. DW-MRI uses the signal loss associated with the random thermal motion of water molecules in the presence of magnetic field gradients to derive parameters that reflect the translational mobility of the water molecules in tissues. If diffusion-weighted images with different values of b matrix are acquired during one individual investigation, it is possible to calculate apparent diffusion coefficient maps that are the elements of the diffusion tensor. The diffusion tensor elements represent the apparent diffusion coefficient of protons of water molecules in each pixel in the corresponding sample. The relation between signal intensity in the diffusion-weighted images, diffusion tensor, and b matrix is derived from the Bloch equations. Our goal is to establish the magnitude of the error made in the calculation of the elements of the diffusion tensor when the imaging gradients are ignored.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The b matrix in diffusion tensor echo-planar imaging.

In diffusion tensor imaging (DTI) an effective diffusion tensor in each voxel is measured by using a set of diffusion-weighted images (DWIs) in which diffusion gradients are applied in a multiplicity of oblique directions. However, to estimate the diffusion tensor accurately, one must account for the effects of all imaging and diffusion gradient pulses on each signal echo, which are embodied in...

متن کامل

Analytical Calculation of the Matrix in Diffusion Imaging

The clinical ability to measure molecular diffusion non­ invasively and in vivo using magnetic resonance imag­ ing (MRI) has generated great interest (1). In tissues, the effective diffusivity depends upon tissue anatomy, microstructure, and gradient pulse parameters. Diffu­ sion MR spectroscopy (2-4), 2DFT spin-echo imaging (5-7), and echo-planar imaging (EPI) (8-11), of in vivo isotropic medi...

متن کامل

Strategies for Assessing Diffusion Anisotropy on the Basis of Magnetic Resonance Images: Comparison of Systematic Errors

Diffusion weighted imaging uses the signal loss associated with the random thermal motion of water molecules in the presence of magnetic field gradients to derive a number of parameters that reflect the translational mobility of the water molecules in tissues. With a suitable experimental set-up, it is possible to calculate all the elements of the local diffusion tensor (DT) and derived paramet...

متن کامل

Diffusion-tensor MR imaging of the human brain with gradient- and spin-echo readout: technical note.

Diffusion-tensor MR imaging of the brain is an objective method that can measure diffusion of water in tissue noninvasively. Five adult volunteers participated in this study that was performed to evaluate the potential of gradient- and spin-echo readout for diffusion-tensor imaging by comparing it with single-shot spin-echo echo-planar imaging. Gradient- and spin-echo readout provides comparabl...

متن کامل

Comparison of Single-Shot Echo-Planar and Line Scan Protocols for Diffusion Tensor Imaging1

Rationale and Objectives. Both single-shot diffusion-weighted echo-planar imaging (EPI) and line scan diffusion imaging (LSDI) can be used to obtain magnetic resonance diffusion tensor data and to calculate directionally invariant diffusion anisotropy indices, ie, indirect measures of the organization and coherence of white matter fibers in the brain. To date, there has been no comparison of EP...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2001