Effect of a Flared Renal Stent on the Performance of Fenestrated Stent-Grafts at Rest and Exercise Conditions
نویسندگان
چکیده
PURPOSE To quantify the hemodynamic impact of a flared renal stent on the performance of fenestrated stent-grafts (FSGs) by analyzing flow patterns and wall shear stress-derived parameters in flared and nonflared FSGs in different physiologic scenarios. METHODS Hypothetical models of FSGs were created with and without flaring of the proximal portion of the renal stent. Flared FSGs with different dilation angles and protrusion lengths were examined, as well as a nonplanar flared FSG to account for lumbar curvature. Laminar and pulsatile blood flow was simulated by numerically solving Navier-Stokes equations. A physiologically realistic flow rate waveform was prescribed at the inlet, while downstream vasculature was modeled using a lumped parameter 3-element windkessel model. No slip boundary conditions were imposed at the FSG walls, which were assumed to be rigid. While resting simulations were performed on all the FSGs, exercise simulations were also performed on a flared FSG to quantify the effect of flaring in different physiologic scenarios. RESULTS For cycle-averaged inflow of 2.94 L/min (rest) and 4.63 L/min (exercise), 27% of blood flow was channeled into each renal branch at rest and 21% under exercise for all the flared FSGs examined. Although the renal flow waveform was not affected by flaring, flow within the flared FSGs was disturbed. This flow disturbance led to high endothelial cell activation potential (ECAP) values at the renal ostia for all the flared geometries. Reducing the dilation angle or protrusion length and exercise lowered the ECAP values for flared FSGs. CONCLUSION Flaring of renal stents has a negligible effect on the time dependence of renal flow rate waveforms and can maintain sufficient renal perfusion at rest and exercise. Local flow patterns are, however, strongly dependent on renal flaring, which creates a local flow disturbance and may increase the thrombogenicity at the renal ostia. Smaller dilation angles, shorter protrusion lengths, and moderate lower limb exercise are likely to reduce the risk of thrombosis in flared geometries.
منابع مشابه
Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries
OBJECTIVE We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. MATERIALS AND METHODS Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were genera...
متن کاملRepair of juxtarenal para-anastomotic aortic aneurysms after previous open repair with fenestrated and branched endovascular stent grafts.
Three patients with juxtarenal para-anastomotic aortic aneurysms after previous open abdominal aortic aneurysm repair were treated with custom-designed fenestrated and branched Zenith endovascular stent grafts. Six renal arteries and two superior mesenteric arteries were targeted for incorporation by graft fenestrations and branches. The fenestration/renal ostium interface was secured with ball...
متن کاملHemodynamic Functions of Fenestrated Stent Graft under Resting, Hypertension, and Exercise Conditions
The aim of this study was to assess the hemodynamic performance of a patient-specific fenestrated stent graft (FSG) under different physiological conditions, including normal resting, hypertension, and hypertension with moderate lower limb exercise. A patient-specific FSG model was constructed from computed tomography images and was discretized into a fine unstructured mesh comprising tetrahedr...
متن کاملHelical CT angiography of fenestrated stent grafting of abdominal aortic aneurysms
Fenestrated stent grafts have been developed to treat patients with abdominal aortic aneurysms (AAA) associated with complicated aneurysm necks, such as short necks, severe angulated or poor quality necks (presence of calcification or thrombus). The technique is performed by creating an opening in the graft material so that the stent graft can be placed above the renal and other visceral branch...
متن کاملVentana fenestrated stent-graft system for endovascular repair of juxtarenal aortic aneurysms.
PURPOSE To describe the initial use of an off-the-shelf fenestrated stent-graft system for endovascular repair of juxtarenal abdominal aortic aneurysms. TECHNIQUE The off-the-shelf Ventana fenestrated stent-graft system consists of a 25-mm IntuiTrak self-expanding bifurcated stent-graft implanted at the aortic bifurcation. A Ventana self-expanding fenestrated proximal extension stent-graft is...
متن کامل