The forced oscillation technique in intubated, mechanically-ventilated patients.

نویسنده

  • K P Van de Woestijne
چکیده

In a recent discussion concerning the use of the forced oscillation technique (FOT), PRIDE [ 1] stated that, although anaesthesia and intensive care are among the obvious areas of application of the method, there is very little information on these applications. The paper by PEsuN et al. [2] in the present issue of the Journal describes one of the first attempts to apply the FOT to mechanicallyventilated patients. FOT, first described by DuBozs et al. [3] in 1956, is a technique in which externally produced pressure oscillations are applied to the respiratory system. The resulting oscillations in airflow, related to the corresponding pressure oscillations, allow a direct measurement of the impedance, i.e. the pressure-flow relationships of the system. Generally, the oscillations are produced by a loudspeaker, and are applied at the mouth of the subject The impedance is calculated from the signals of a pressure transducer and a pneumotachograph placed close to the subject's mouth. Because of the complex mechanical properties of the respiratory system, consisting of various structures with capacitive (compliant), resistive and inertive properties, pressure and flow signals are not in phase (except at given frequencies, called resonant frequencies): recorded in X-Y coordinates, the pressure-flow relationships describe a loop. Therefore, the impedance is characterized by a modulus, IZI, the ratio of pressure versus airflow, and a phase, <p, expressing the shift in time of these two variables. Another, more usual, way of dealing with this time shift is to divide the impedance into a real part or resistance (R), and an imaginary part or reactance (X), in which R is IZI cos <p, and X is lZI sin <p. In a simple circuit, consisting of a capacity, a resistance and an inertance, coiUlected in series, R corresponds to the actual resistance of the circuit and X to a combination of capacity and inertance. Generally, in a complex system, Rand X vary with oscillatory frequency. Therefore, to define the mechanical properties of the respiratory system, R and X are measured at various frequencies. In the original device of DuBms et al. [3], the response of the respiratory system was investigated by applying a succession of oscillations varying in frequency, during voluntary apnoea. This took time, and made the technique very impractical. This is why the FOT did not gain widespread acceptance, until it was modified so that sev-

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Servocontrolled generator to measure respiratory impedance from 0.25 to 26 Hz in ventilated patients at different PEEP levels.

Assessing respiratory impedance (Zrs) in ventilated patients over a wide frequency band, ranging from breathing rates to typical forced oscillation frequencies, during end-expiratory pauses at different positive end-expiratory pressures (PEEP) is of potential interest to assess a patient's respiratory mechanics. Zrs measurements under these conditions are not possible with the present variants ...

متن کامل

Respiratory mechanics studied by forced oscillations during artificial ventilation.

Potential advantages of the forced oscillation technique over other methods for monitoring total respiratory mechanics during artificial ventilation are that it does not require patient relaxation, and that additional information may be derived from the frequency dependence of the real (Re) and imaginary (Im) parts of respiratory impedance. We wanted to assess feasibility and usefulness of the ...

متن کامل

Perioperative evaluation of respiratory impedance using the forced oscillation technique: a prospective observational study

BACKGROUND Intravascular fluid shifts, mechanical ventilation and inhalational anesthetic drugs may contribute to intraoperative lung injury. This prospective observational study measured the changes in respiratory impedance resulting from inhalational anesthesia and mechanical ventilation in adults undergoing transurethral resection of bladder tumors. The components of respiratory impedance (r...

متن کامل

Effect of Oral Drop Gastrolit (Zataria multiflora) on Gastric Residual Volume in Mechanically Ventilated Patients Hospitalized in the Intensive Care Units

Background: Proper nutritional support is one of the important caring aspects in patients who were hospitalized in ICU. Objective: This study was done to investigate Oral Drop Gastrolit effect on the gastric residual volume (GRV) in mechanically ventilated patients hospitalized in ICU. Methods: In this clinical trial, 50 mechanically ventilated patients were recruited using convenience sampli...

متن کامل

The Effects of Rib Cage Compression before endotracheal suctioning

Abstract Introduction: Accumulation of secretions in airways is a serious complication in intubated and mechanically ventilated patients. Tracheal suctioning which is done with the aim of secretion removal can be used in conjunction with physiotherapy for effective airway clearance and improving gas exchange. Objective: The aim of study was to determine the effects of rib cage compression befor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 6 6  شماره 

صفحات  -

تاریخ انتشار 1993