Correction: Temperature of gas delivered from ventilators

نویسندگان

  • Yusuke Chikata
  • Masayo Izawa
  • Hideaki Imanaka
  • Nao Okuda
  • Masaji Nishimura
چکیده

[This corrects the article on p. 6 in vol. 1, PMID: 25705400.].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Temperature of gas delivered from ventilators

BACKGROUND Although heated humidifiers (HHs) are the most efficient humidifying device for mechanical ventilation, some HHs do not provide sufficient humidification when the inlet temperature to the water chamber is high. Because portable and home-care ventilators use turbines, blowers, pistons, or compressors to inhale in ambient air, they may have higher gas temperature than ventilators with ...

متن کامل

RESPIRATION AND THE AIRWAY Delivery of tidal volume from four anaesthesia ventilators during volume-controlled ventilation: a bench study

Editor’s key points † This study investigated the accuracy of delivered tidal volume in four new ventilators under different conditions. † Set and delivered tidal volumes differed when compliance and resistance were changed, although the effect of fresh gas flow was less. † Some of the new ventilators tested were more accurate than others. † The clinical significance of these findings is uncert...

متن کامل

Local Field Correction Effect on Dicluster Stopping Power in a Strongly Coupled Two-Dimensional Electron Gas System

We calculate the stopping power for heavy-ion diclusters moving in a strongly coupled two-dimensional electron gas system by using the local field corrected dielectric function at finite temperature. We obtain a parameterized local field correction factor based on a relation between the thermal compressibility and exchange-correlation energy in two-dimension. The interpolated parameter is deriv...

متن کامل

Delivery of tidal volume from four anaesthesia ventilators during volume-controlled ventilation: a bench study.

BACKGROUND Tidal volume (V(T)) must be accurately delivered by anaesthesia ventilators in the volume-controlled ventilation mode in order for lung protective ventilation to be effective. However, the impact of fresh gas flow (FGF) and lung mechanics on delivery of V(T) by the newest anaesthesia ventilators has not been reported. METHODS We measured delivered V(T) (V(TI)) from four anaesthesia...

متن کامل

Evaluation of 4 new generation portable ventilators.

BACKGROUND Portable ventilators are increasingly utilized in the intra- and inter-hospital transport of patients. We evaluated 4 portable ventilators, Impact EMV, CareFusion LTV 1200, Newport HT70, and Hamilton T1, in terms of triggering, delivered tidal volume (V(T)) accuracy, battery duration, delivered F(IO(2)) accuracy, and gas consumption. METHODS Triggering was tested using a microproce...

متن کامل