Shot-noise Limited Faraday Rotation Spectroscopy for Detection of Nitric Oxide Isotopes in Breath, Urine, and Blood

نویسندگان

  • Yin Wang
  • Michal Nikodem
  • Eric Zhang
  • Frank Cikach
  • Jarrod Barnes
  • Suzy Comhair
  • Raed A. Dweik
  • Christina Kao
  • Gerard Wysocki
چکیده

Measurement of NO and/or its metabolites in the various body compartments has transformed our understanding of biology. The inability of the current NO measurement methods to account for naturally occurring and experimental NO isotopes, however, has prevented the scientific community from fully understating NO metabolism in vivo. Here we present a mid-IR Faraday rotation spectrometer (FRS) for detection of NO isotopes. The instrument utilizes a novel dual modulation/demodulation (DM) FRS method which exhibits noise performance at only 2 times the fundamental quantum shot-noise level and provides the record sensitivity in its class. This is achieved with a system that is fully autonomous, robust, transportable, and does not require cryogenic cooling. The DM-FRS enables continuous monitoring of nitric oxide isotopes with the detection limits of 3.72 ppbv/Hz(1/2) to(14)NO and 0.53 ppbv/Hz(1/2) to(15)NO using only 45 cm active optical path. This DM-FRS measurement method can be used to improve the performance of conventional FRS sensors targeting other radical species. The feasibility of the instrument to perform measurements relevant to studies of NO metabolism in humans is demonstrated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nitric Oxide Isotopic Analyzer Based on a Compact Dual-Modulation Faraday Rotation Spectrometer

We have developed a transportable spectroscopic nitrogen isotopic analyzer. The spectrometer is based on dual-modulation Faraday rotation spectroscopy of nitric oxide isotopologues with near shot-noise limited performance and baseline-free operation. Noise analysis indicates minor isotope ((15)NO) detection sensitivity of 0.36 ppbv·Hz(-1/2), corresponding to noise-equivalent Faraday rotation an...

متن کامل

Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection.

Tunable-laser absorption spectroscopy in the mid-IR spectral region is a sensitive analytical technique for trace-gas quantification. The detection of nitric oxide (NO) in exhaled breath is of particular interest in the diagnosis of lower-airway inflammation associated with a number of lung diseases and illnesses. A gas analyzer based on a continuous-wave mid-IR quantum cascade laser operating ...

متن کامل

Ultrasensitive detection of nitric oxide at 5.33 microm by using external cavity quantum cascade laser-based Faraday rotation spectroscopy.

A transportable prototype Faraday rotation spectroscopic system based on a tunable external cavity quantum cascade laser has been developed for ultrasensitive detection of nitric oxide (NO). A broadly tunable laser source allows targeting the optimum Q(3/2)(3/2) molecular transition at 1875.81 cm(-1) of the NO fundamental band. For an active optical path of 44 cm and 1-s lock-in time constant m...

متن کامل

Faraday rotation spectrometer with sub-second response time for detection of nitric oxide using a cw DFB quantum cascade laser at 5.33 μm

A Faraday modulation spectrometer for sensitive and fast detection of nitric oxide at 5.33 μm utilizing a room temperature continuous wave distributed feedback quantum cascade laser and a Peltier cooled MCT detector is presented. The magnetic field was modulated at 7.4 kHz whereas the laser wavelength was scanned at 20 Hz across the most favorable rotational-vibrational transition for FAMOS, Q3...

متن کامل

Laser-induced fluorescence spectroscopy of 14N18O and its application to breath analysis.

Laser-induced fluorescence (LIF) spectroscopy is an efficient tool for the detection of low nitric oxide (NO) concentrations down to the parts per trillion (ppt) range. The isotopic selectivity of this method provides a broad potential of applications. Whereas (14)N(16)O and (15)N(16)O have been described extensively this is not the case for the (14)N(18)O isotopologue. A (1+1) resonance enhanc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015