Comparative study of two control strategies for Shunt Active Power Filter (SAPF) in 3-ph, 3-wire system using PI controller
نویسندگان
چکیده
Due to large amount of non-linear power electronic equipment’s impact and fluctuating loads, problems of power quality have become more and more serious with each passing day. Active power filtering has gained much more importance in the power quality arena as it gives the best solution for all power quality issues. Shunt active filtering is effective and the performance of such units largely depends upon the control strategies used for reference current generation. This paper presents the comparative evaluation of the performance of two control techniques to determine the reference current for the three phase three wire SAPF in order to improve the power quality using PI controller. The first one is based on the Instantaneous real and reactive power (p-q) method and second one is the Instantaneous active and reactive current (Id-Iq) method. Both control techniques are based on time domain simulated with Matlab/Simulink. Different simulation results are presented with and without SAPF under balanced condition in this paper.
منابع مشابه
Comparative Analysis between PI and Fuzzy Controllers for Dc Voltage Control of Unbalanced 4 Wire Shunt Active Power Filter
This research proposes a shunt active power filter (SAPF) for harmonics mitigation in order to improve power quality of the electrical network. The reference harmonic current extraction technique used was based on DQ0 power theory under unbalanced non-linear loads conditions for four wire-installed systems. The DC-link voltage plays an important role in SAPF design to guarantee both steady high...
متن کاملA Hybrid Control Method for Stable Operation of Active Power Filters in Three-Phase Four-Wire Networks
The main goal of this study is the use of Lyapunov’s stability theory to a three-phase four-wire shunt active power filter (SAPF), since this method has been applied effectively to other areas of converter. The dynamic model of the SAPF is first established, after that, a combination of fuzzy tracking control and Lyapunov function is suggested in order to impose a desired transient waveform on ...
متن کاملHarmonic Mitigation using Fuzzy Logic Controller based Shunt Active Power Filter
Power quality problem is t he most sensitive problem in the power system. The objective of the project is to reduce one of the power quality issue called “harmonics” using compensation technique. Shunt Active Power Filter (SAPF) is used to eliminate harmonic current and also it compensates reactive power. In this project, both PI controller and Fuzzy Logic Controller based three-phase shunt act...
متن کاملHysteresis Control for Current Harmonics Suppression Using Shunt Active Filter
Recently wide spread of power electronic equipment has caused an increase of the harmonic disturbances in the power systems. The nonlinear loads draw harmonic and reactive power components of current from ac mains. Current harmonics generated by nonlinear loads such as adjustable speed drives, static power supplies and UPS. Thus a perfect compensator is required to avoid the consequences due to...
متن کاملEnhancement of Power Quality in Grid Integrated System using DC-link Voltage PI Controlled VSC based Statcom
This paper demonstrates an enhancement of power quality in grid integrated systems with the help of the proposed control strategy for voltage source converter based active power filters. The Shunt Active Power filters (SAPF) are extensively utilized in modern grid integrated systems to diminish the power quality concerns associated with it. The SAPF is one of the various power filters, which ha...
متن کامل