Numerical modelling of the seismic behaviour of a 7-story building: NEES benchmark
نویسندگان
چکیده
The American NEES Consortium Inc. (NEESinc) has performed a seismic research project around an uniaxial shaking table test on a structure representing a full-scale vertical slice of a 7-story reinforced concrete wall building. This paper deals with the numerical strategy adopted in the laboratory 3S-R for a ‘‘blind’’ simulation of the non linear behaviour of the specimen. Multifiber Timoshenko beam elements are used for the finite element mesh of the reinforced concrete walls. Constitutive models are based on damage mechanics for concrete and plasticity for steel. It is shown that the proposed modelling strategy describes accurately the global behaviour of the structure (even though the prediction is ‘‘blind’’). Then, comparison with the experimental results helps to identify the deficiencies of the original numerical model and to propose remedies in order to improve its performance. Based on the results obtained it appears possible to use this approach to investigate numerically the behaviour of a wider variety of configurations that is practically impossible to study experimentally.
منابع مشابه
Evaluation of Seismic Vulnerability of Reinforced Concrete Buildings Adjacent to the Deep Excavations
In this study, the effect of deep excavation on the seismic response of RC moment resisting building systems has been studied. Deep excavation can cause significant changes in the stress and strain levels of soil environment and also changes in the propagation of seismic waves. This leads to permanent displacements in the foundation system. In this study, three RC building systems, i.e. 5, 10, ...
متن کاملEstimating the inter-story drift in high rise buildings with the flexural and shear cantilever beam and mode-acceleration method
In this study, the seismic inter-story drift of structures is estimated by a combination of mode-acceleration equations with the modelling of high-rise buildings with flexural and shear cantilever beams. In the equation presented for calculating the inter-story drift, having less knowledge of the building is adequate and this issue is of significance in estimating the nonstructural component fo...
متن کاملSEMI-ACTIVE NEURO-CONTROL FOR MINIMIZING SEISMIC RESPONSE OF BENCHMARK STRUCTURES
This article presents numerical studies on semi-active seismic response control of structures equipped with Magneto-Rheological (MR) dampers. A multi-layer artificial neural network (ANN) was employed to mitigate the influence of time delay, This ANN was trained using data from the El-Centro earthquake. The inputs of ANN are the seismic responses of the structure in the current step, and the ou...
متن کاملSeismic Performance of Torsionally Stiff and Flexible Single Story Buildings Designed Based on Iranian Seismic Code(Standard 2800)
This paper examines differences in performances of a range of torsionally stiff and flexible single story buildings designed with the provisions of Iranian Standard 2800. Seismic nonlinear dynamic time history behavior of eight building models subjected to seven horizontal bi-directional design spectra compatible ground motions are investigated. These models cover a wide range of very torsional...
متن کاملSeven-story Building Subjected to Seismic Loading: Experimentation and Modeling
This article presents a research program on a structure representing a seven-story residential building tested on the shaking table in the NEES [6]. The building was designed using a displacement based capacity approach for a site in Los Angeles resulting design lateral force. The structure is composed of 2 main perpendicular walls connected by slotted connections. The numerical calculations ha...
متن کامل