Automated chemiluminescence-immunoassay for aldosterone during dynamic testing: comparison to radioimmunoassays with and without extraction steps.

نویسندگان

  • Caroline Schirpenbach
  • Lysann Seiler
  • Christiane Maser-Gluth
  • Felix Beuschlein
  • Martin Reincke
  • Martin Bidlingmaier
چکیده

BACKGROUND Measurements of aldosterone have become more common since the recognition that primary aldosteronism is a more frequent cause of hypertension than previously believed. Our aim was to compare concentrations reported by 4 assays for samples obtained after saline infusion during dynamic testing. METHODS We tested 104 participants (27 with primary aldosteronism, 30 with essential hypertension, and 47 healthy controls) with the intravenous saline infusion test (2.0 L isotonic saline over 4 h), with repetitive sampling. In all blood samples, aldosterone concentration was measured by an in-house RIA after extraction and chromatography, by 2 commercially available RIAs without extraction (Aldosterone Maia, Adaltis; Active Aldosterone, Diagnostics Systems Laboratories) and by an automated CLIA (Advantage, Nichols Institute Diagnostics). RESULTS Correlation coefficients for results of pairs of assays ranged from 0.74 to 0.98. Agreement between commercial assays and in-house RIA was best at the low to intermediate concentrations after saline infusion. Mean (SD) Adaltis and DSL RIA results were 2- to 3-times higher [healthy participants: 78 (25) ng/L and 56 (18) ng/L, respectively] than those obtained by Nichols CLIA [17 (8) ng/L] and in-house RIA [23 (18) ng/L]. Aldosterone concentrations measured by the Nichols CLIA were below the limit of detection (limit of the blank) in 27 of 47 healthy participants. CONCLUSIONS Aldosterone concentrations reported by the Adaltis and DSL nonextraction RIAs were consistently higher than those produced by the Nichols CLIA and the in-house RIA. The convenient Nichols CLIA showed better agreement with the in-house RIA, but the concentrations in healthy participants were frequently undetectable by this method. Uncritical application of cutoff values from the literature must be avoided.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stabilization of glucose in blood specimens: mechanism of delay in fluoride inhibition of glycolysis.

1. Wion-Barbot N, Schuffenecker I, Niccoli P, Conte-Devolx B, Lecomte P, Houdent C, et al. Results of the calcitonin stimulation test in normal volunteers compared with genetically unaffected members of MEN 2A and familial medullary thyroid carcinoma families. Ann Endocrinol (Paris) 1997;58:302–8. 2. Motte P, Vauzelle P, Gardet P, Ghillani P, Caillou B, Parmentier C, et al. Construction and cli...

متن کامل

Chemiluminescence immunoassay of aldosterone in serum.

A chemiluminescence immunoassay (CLI) for the direct measurement of aldosterone in serum was developed with aminobutylethyl isoluminol (ABEI) as the label. In this competitive assay the samples are incubated with sample, antibody, aldosterone-carboxymethyl oxime-ABEI, and paramagnetic particles coated with second antibody. After magnetic separation and washing, the samples are incubated with 20...

متن کامل

Direct determination of plasma endothelin-I by chemiluminescence enzyme immunoassay.

A highly sensitive sandwich-type chemiluminescence enzyme immunoassay for plasma endothelin-I (ET-1), involving no extraction steps, has been developed. Two populations of polyclonal antibodies were used in the present study: One is specific to the C-terminus of the endothelin family of peptides; the other, a Fab' fragment against the N-terminal core region of ET-1, is coupled with horseradish ...

متن کامل

Evaluation of LIAISON Treponema Screen, a novel recombinant antigen-based chemiluminescence immunoassay for laboratory diagnosis of syphilis.

The purpose of this study was to evaluate the diagnostic performance of LIAISON Treponema Screen (DiaSorin, Saluggia, Italy), a new automated chemiluminescence immunoassay (CLIA), in comparison with that of rapid plasma reagin (RPR) and the following currently used treponemal tests: hemagglutination test (TPHA), immunoenzymatic assay (EIA), and Western blot (WB). First, a retrospective study wa...

متن کامل

Homogeneous immunoassay based on chemiluminescence energy transfer.

The chemiluminescent compound aminobutylethyl-isoluminol (ABEI) and its isothiocyanate derivative have been coupled to a range of haptens (progesterone, cyclic AMP, cyclic GMP) and protein antigens (IgG, C9). All the derivatives were chemiluminescent, immunologically active, and stable for more than six months. When the ABEI-labeled antigens bind to their respective fluorescein-labeled antibodi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 52 9  شماره 

صفحات  -

تاریخ انتشار 2006