A simulation study of an inverse controller for closed- and semiclosed-loop control in type 1 diabetes.

نویسندگان

  • Agustín Rodríguez-Herrero
  • Carmen Pérez-Gandía
  • Mercedes Rigla
  • Alberto de Leiva
  • Enrique J Gómez
  • M Elena Hernando
چکیده

BACKGROUND Closed-loop control algorithms in diabetes aim to calculate the optimum insulin delivery to maintain the patient in a normoglycemic state, taking the blood glucose level as the algorithm's main input. The major difficulties facing these algorithms when applied subcutaneously are insulin absorption time and delays in measurement of subcutaneous glucose with respect to the blood concentration. METHODS This article presents an inverse controller (IC) obtained by inversion of an existing mathematical model and validated with synthetic patients simulated with a different model and is compared with a proportional-integral-derivative controller. RESULTS Simulated results are presented for a mean patient and for a population of six simulated patients. The IC performance is analyzed for both full closed-loop and semiclosed-loop control. The IC is tested when initialized with the heuristic optimal gain, and it is compared with the performance when the initial gain is deviated from the optimal one (+/-10%). CONCLUSIONS The simulation results show the viability of using an IC for closed-loop diabetes control. The IC is able to achieve normoglycemia over long periods of time when the optimal gain is used (63% for the full closed-loop control, and it is increased to 96% for the semiclosed-loop control).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Near Optimal High Gain Controller For The Non-Minimum Phase Affine Nonlinear Systems

In this paper, a new analytical method to find a near-optimal high gain controller for the non-minimum phase affine nonlinear systems is introduced. This controller is derived based on the closed form solution of the Hamilton-Jacobi-Bellman (HJB) equation associated with the cheap control problem. This methodology employs an algebraic equation with parametric coefficients for the systems with s...

متن کامل

Control of Flexible Link Robot using a Closed Loop Input-Shaping Approach

This paper is has addressed the Single Flexible Link Robot. The dynamical model is derived using Euler-Lagrange equation and then a proper controller is designed to suppress a  vibration based-on Input-Shaping (IS) method. But, IS control method is an open loop strategy. Due to the weakness of open loop control systems, a closed loop IS control system is proposed. The achieved closed loop c...

متن کامل

A Closed Loop Control of Quadratic Boost Converter Using PID Controller

This paper presents an implementation of open loop and closed loop control of Quadratic boost converter using PID controller.  Quadratic boost converter consists of boost converter and fly back converter driven by a single switch. Quadratic boost converter QBC is designed especially for regulating the DC interface between various micro sources and dc-ac inverter to electricity grid. Quadratic b...

متن کامل

An efficient method to control the amplitude of the limit cycle in satellite attitude control system

In this paper, an efficient method is presented to control the attitude of a satellite with ON-OFF actuator. The main objective of this novel method is to control the amplitude of the limit cycle which commonly appears in the steady state of such systems; and at the same time by consideration of real actuator constraints, reduce the fuel consumption of system. The Proposed method is a combinati...

متن کامل

The Design of a New Double Loop Controller For Simultaneous Adjustment of Input and Output Voltages of Single-Phase Grid-Connected Inverter

Although LCL filters are used widely in the grid connected inverters to reduce high-orderharmonics, such a system increases system order and therefore sustainable design of closed-loopcontroller system will be complicated. Recently, the single-loop control strategy has beensuggested for L or LC filter based grid-connected inverters. However, the use of single-loopcontrol directly in LCL filter-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diabetes technology & therapeutics

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 2010