A simplified hot-wire cutting aid for PVC trays used in radioimmunoassay.

نویسندگان

  • A Anderson
  • G Fleming
  • C D Inskip
  • G K Scott
چکیده

The ease and convenience of a hot-wire cutter for the separation of wells from PVC radioimmunoassay trays has been demonstrated.' In constructing a similar apparatus, it was felt that a worthwhile simplification could be achieved by arranging to push the PVC tray past a fixed hot wire. The wire can simply be held under spring tension, and the springloaded telescopic arm previously employed' be eliminated. We feel that this modification may be of interest to laboratories without access to sophisticated workshop facilities. The general layout of the apparatus is shown in Fig. 1 (a) and (b). The baseboard is laminated from two layers of 12 mm plywood. Basically the apparatus consists of a heated wire stretched between two rails which guide the PVC tray as it is pushed past the wire. Each rail has a shoulder which permits the tray to sit proud of a rubber centrifuge block moulded to hold the wells of the tray. The rails are each machined in two pieces from solid PVC, but could readily be laminated from sheet plastic or plywood. Two PVC strips are screwed between the tops of the rails to prevent the tray from rising during the cutting operation. A laminated PVC block fits between the rails and is used to push the tray and support block past the heated wire by means of a handle of 20 mm diameter PVC rod. The outer rail is drilled to clear a brass terminal rod mounted through the upper layer of the baseboard. One end of the 26 g Nichrome wire is held in a horizontal hole in this terminal by a set screw. The wire is then threaded through a second brass rod set into the inner rail and is looped and secured to a spring. The spring exerts a force of 1150 g on the cold wire. By angling the spring away from the line of the wire between the terminals, a good electrical contact with the inner terminal is ensured. Screw threads on the terminals allow the height of the cutting wire to be varied. An isolating transformer with a nominal output of 12 V and 8 A is fitted, as previously suggested.' To achieve optimal heating with a 120 mm cutting wire, a further 275 mm is wired in series to provide the appropriate resistance. This is conveniently done

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using the Finite Element Method to Determine the Temperature Distributions in Hot-wire Polystyrene Cutting

Hot-wire cutting is a common material removal process used to shape and sculpt plastic foam materials, such as expanded polystyrene (EPS). Due to the low cost and sculpt-ability of plastic foams they are popular materials for large sized (> 1 m3) prototypes and bespoke visual artefacts. Recent developments in robotic foam sculpting machines have greatly increased the ability of hot-tools to scu...

متن کامل

Analysis of PVC Frames Cutting by Guillotine and Presenting Solution on Preventing Imperfection

PVC frame cutting process by guillotine is a common method that attracted attention of car parts and PVC decorating furniture producers. In this paper, the effects of main parameters such as cutting speed, lubricants and cutting frame holder pressure force on PVC frame section surface smoothness is investigated by experimental methods on a specified PVC frame sample and then by FEM simulation u...

متن کامل

The plastic tray effect on the spectrum of photoneutrons prudused by 18 MV medical linac using the Monte Carlo method

Introduction: One of the important problems of using high energy linacs is the production of photoneutrons. High energy medical linacs produce secondary neutrons. These phtoneutrons increase patient dose   Materials and Methods: In this study, the effect of plastic trays on spectrum of photoneutrons produced by 18MV linac is investigated using the MCNP4C code...

متن کامل

Rectal wall dose estimation in intracavitary brachytherapy: A preliminary comparison of an in-house rectal wire versus ICRU 38 recommendations

Background: In intracavitary brachytherapy for gynecological cancers, various techniques are used to locate the anterior rectal wall nearest to the sources but there is no consensus on the best method to do so. This study aimed to compare a technique used routinely in some centers that employs a wire marker to locate the position of the maximum rectal dose point, versus the method recommended b...

متن کامل

Flow Visualization by Conditional Sampling of a Single X-Wire Probe in a Very Long Run Experiment

Flow visualization techniques using tracer markers such as die, smoke, hydrogen bubbles, etc., have been widely used in experimental investigations of large scale structures of a variety of flow fields. They have played an important role in understanding the physics of the coherent structures formation and evolution in the transitional as well as the turbulent regions of the flow fields. Howeve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 36 12  شماره 

صفحات  -

تاریخ انتشار 1983