PURPOSE We determine the value of color mapping of bladder wall thickness for detection of tumor as a component of virtual cystoscopy. MATERIALS AND METHODS A total of 31 subjects with hematuria and/or a history of bladder tumor underwent helical computerized tomography of the pelvis after distention of the bladder with air. Three-dimensional (D) models were constructed, and thickness of the wall was color mapped according to a fixed and validated mm. scale. Axial source images and 3-D models were reviewed and graded for the presence of wall thickening. A comparison was made with findings on conventional cystoscopy in 31 patients and pathological specimen in 13. RESULTS Compared with conventional cystoscopy, the analysis of axial image yielded a sensitivity of 0.80, specificity 0.90, positive predictive value 0.80 and negative predictive value 0.90 for the presence of tumor. Examination of color mapped 3-D renderings resulted in 0.83, 0.36, 0.42 and 0.71, respectively. CONCLUSIONS Thin axial computerized tomography of the air distended bladder shows promise as a potential screening tool for bladder cancer. The low specificity of color mapped 3-D renderings makes the technique inappropriate for screening. It may valuable for guiding urologists to additional suspicious sites in a patient with a known tumor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Virtual CT cystoscopy: color mapping of bladder wall thickness.

RATIONALE AND OBJECTIVES To improve the conspicuity of bladder tumors in a virtual environment, we developed an algorithm for color mapping the thickness of the bladder wall. The purpose of this study was to demonstrate the feasibility of this algorithm as a component of virtual CT cystoscopy. METHODS Five subjects with a history of superficial transitional-cell carcinoma of the bladder under...

متن کامل

Computer-aided detection of bladder tumors based on the thickness mapping of bladder wall in MR images [7623-161]

Bladder cancer is reported to be the fifth leading cause of cancer deaths in the United States. Recent advances in medical imaging technologies, such as magnetic resonance (MR) imaging, make virtual cystoscopy a potential alternative with advantages as being a safe and non-invasive method for evaluation of the entire bladder and detection of abnormalities. To help reducing the interpretation ti...

متن کامل

Computer-aided detection of bladder tumors based on the thickness mapping of bladder wall in MR images

Bladder cancer is reported to be the fifth leading cause of cancer deaths in the United States. Recent advances in medical imaging technologies, such as magnetic resonance (MR) imaging, make virtual cystoscopy a potential alternative with advantages as being a safe and non-invasive method for evaluation of the entire bladder and detection of abnormalities. To help reducing the interpretation ti...

متن کامل

Bladder wall flattening with conformal mapping for MR cystography

Magnetic resonance visual cystoscopy or MR cystography (MRC) is an emerging tool for bladder tumor detection, and 3D endoscopic views on the inner bladder surface are being investigated by researchers. In this paper, we further investigate an innovative strategy of visualizing the inner surface by flattening the 3D surface into a 2D display, where conformal mapping, a mathematically-proved algo...

متن کامل

Bladder wall flattening with conformal mapping for MR cystography [7625-13]

Magnetic resonance visual cystoscopy or MR cystography (MRC) is an emerging tool for bladder tumor detection, where three-dimensional (3D) endoscopic views on the inner bladder surface are being investigated by researchers. In this paper, we further investigate an innovative strategy of visualizing the inner surface by flattening the 3D surface into a 2D display, where conformal mapping, a math...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of urology

دوره 167 2 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2002