Total corneal power estimation: ray tracing method versus gaussian optics formula.

نویسندگان

  • Li Wang
  • Ashraf M Mahmoud
  • Betty Lise Anderson
  • Douglas D Koch
  • Cynthia J Roberts
چکیده

PURPOSE To evaluate with the use of corneal topographic data the differences between total corneal power calculated using ray tracing (TCP) and the Gaussian formula (GEP) in normal eyes, eyes that previously underwent laser in situ keratomileusis/photorefractive keratectomy (LASIK/PRK), and theoretical models. METHODS TCP and GEP using mean instantaneous curvature were calculated over the central 4-mm zone in 94 normal eyes, 61 myopic-LASIK/PRK eyes, and 9 hyperopic-LASIK/PRK eyes. A corneal model was constructed to assess the incident angles at the posterior corneal surface for both refracted rays and parallel rays. Corneal models with varying parameters were also constructed to investigate the differences between mean TCP and GEP (4-mm zone), and an optical design software validation was performed. RESULTS The TCP values tended to be less than GEP in normal and myopic-LASIK/PRK eyes, with the opposite relationship in some hyperopic-LASIK/PRK eyes having the highest anterior surface curvature. The difference between TCP and GEP was a function of anterior surface instantaneous radii of curvature and posterior/anterior ratio in postrefractive surgery eyes but not in normal eyes. In model corneas, posterior incident angles with parallel rays were greater than those with refracted rays, producing an overestimation of negative effective posterior corneal power; differences in magnitude between TCP and GEP increased with decreasing ratio of posterior/anterior radii of curvature, consistent with clinical results. CONCLUSIONS In eyes after refractive surgery, calculating posterior corneal power using the Gaussian formula and its paraxial assumptions introduces errors in the calculation of total corneal power. This may generate errors in intraocular lens power calculation when using the Gaussian formula after refractive surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Posterior corneal astigmatism.

In the optical system of the human eye, total refractive power consists mainly of corneal and lenticular components. Approximately two-thirds of the eye's converging power is at the air–cornea (tear film) interface; one-third is in the lens. Total corneal power is determined by corneal anterior and posterior curvature, corneal thickness, and the corneal refractive indices. Traditionally, anteri...

متن کامل

Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula.

PURPOSE To describe a new formula, BESSt, to estimate true corneal power after keratorefractive surgery in eyes requiring cataract surgery. SETTING Moorfields Eye Hospital, London, United Kingdom. METHODS The BESSt formula, based on the Gaussian optics formula, was developed using data from 143 eyes that had keratorefractive surgery. The formula takes into account anterior and posterior cor...

متن کامل

Quasi-optical Beam Waveguide Analysis Using Gaussian Beam Expansion

For reflector antennas and mirrors with diameters < 50 ? Physical Optics (PO) and the Physical Theory of Diffraction (PTD) are very fast and accurate calculation methods for determining the scattered fields. In optics where the diameter of the mirrors >> 1000 ? ray tracing methods are sufficient means of determining the scattered fields. However, in the Quasi-optical range in between these wave...

متن کامل

Positional accommodative intraocular lens power error induced by the estimation of the corneal power and the effective lens position

PURPOSE To evaluate the predictability of the refractive correction achieved with a positional accommodating intraocular lenses (IOL) and to develop a potential optimization of it by minimizing the error associated with the keratometric estimation of the corneal power and by developing a predictive formula for the effective lens position (ELP). MATERIALS AND METHODS Clinical data from 25 eyes...

متن کامل

Effect of corneal aberrations on intraocular lens power calculations.

PURPOSE To use ray tracing to determine the influence of corneal aberrations on the prediction of the optimum intraocular lens (IOL) power for implantation in normal eyes and eyes with previous laser in situ keratomileusis (LASIK). SETTING Hospital Universitario Virgen de la Arrixaca, Murcia, Spain. DESIGN Case series. METHODS The optimum IOL power was calculated by ray tracing using a pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 3  شماره 

صفحات  -

تاریخ انتشار 2011