Improvement of transcutaneous fluorescent images with a depth-dependent point-spread function.

نویسندگان

  • Koichi Shimizu
  • Koji Tochio
  • Yuji Kato
چکیده

The point-spread function (PSF) for transcutaneous fluorescent imaging was obtained as an analytical solution in a closed form. It is applicable to cases in which the optical property of the image-blurring turbid medium is considered to be fairly homogeneous. We proposed a technique to improve a transcutaneous image by using depth-dependent PSF. Contrast of the fluorescent image was improved for depths of 1-15 mm in a scattering medium (micro(s)' = 1/mm). The visible depth was more than doubled with this technique. An experiment with a rat demonstrated considerable improvement of a transcutaneous image of the cerebral vein at a specified depth. The spread image of the heart was reduced to the correct size by use of the PSF with the actual depth of the heart.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Edge Artifacts in Point Spread Function-based PET Reconstruction in Relation to Object Size and Reconstruction Parameters

Objective(s): We evaluated edge artifacts in relation to phantom diameter and reconstruction parameters in point spread function (PSF)-based positron emission tomography (PET) image reconstruction.Methods: PET data were acquired from an original cone-shaped phantom filled with 18F solution (21.9 kBq/mL) for 10 min using a Biograph mCT scanner. The images were reconstructed using the baseline or...

متن کامل

Evaluation of the Effect of Tumor Position on Standardized Uptake Value Using Time-of-Flight Reconstruction and Point Spread Function

Objective(s): The present study was conducted to examine whether the standardized uptake value (SUV) may be affected by the spatial position of a lesion in the radial direction on positron emission tomography (PET) images, obtained via two methods based on time-of-flight (TOF) reconstruction and point spread function (PSF). Methods: A cylinder phantom with the sphere (30mm diameter), located in...

متن کامل

Two-dimensional advection-dispersion equation with depth- dependent variable source concentration

The present work solves two-dimensional Advection-Dispersion Equation (ADE) in a semi-infinite domain. A variable source concentration is regarded as the monotonic decreasing function at the source boundary (x=0). Depth-dependent variables are considered to incorporate real life situations in this modeling study, with zero flux condition assumed to occur at the exit boundary of the domain, i.e....

متن کامل

Two-dimensional advection-dispersion equation with depth- dependent variable source concentration

The present work solves two-dimensional Advection-Dispersion Equation (ADE) in a semi-infinite domain. A variable source concentration is regarded as the monotonic decreasing function at the source boundary (x=0). Depth-dependent variables are considered to incorporate real life situations in this modeling study, with zero flux condition assumed to occur at the exit boundary of the domain, i.e....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 44 11  شماره 

صفحات  -

تاریخ انتشار 2005