Stamp transfer electrodes for electrochemical sensing on non-planar and oversized surfaces.

نویسندگان

  • Joshua Ray Windmiller
  • Amay Jairaj Bandodkar
  • Serguey Parkhomovsky
  • Joseph Wang
چکیده

This article describes a new alternative approach to the fabrication of printed electrochemical sensors and biosensors based on the transfer of electrode patterns comprising common conductive and insulating inks from elastomeric stamps to a wide variety of rigid and flexible substrates. This simple, low cost, yet robust methodology is demonstrated to be well-suited for the formation of electrochemical sensors on non-planar substrates and large objects/structures, which have traditionally been off-limits to conventional screen printing techniques. Furthermore, the stamped electrode devices are shown to exhibit electrochemical performance that rivals that of their screen printed counterparts and display resilience against severe mechanical deformation. The stamp transfer approach is further extended to the demonstration of epidermal electrochemical sensors through the transfer of the electrode patterns directly onto the skin. The resulting sensors demonstrate a wide range of usability, from the detection of various physiological analytes, including uric acid on the skin, to the identification of residues originating from the handling of munitions and explosives. The migration of printable electrochemical sensors to non-conventional (non-planar and/or oversized) surfaces provides new opportunities within the personal healthcare, fitness, forensics, homeland security, and environmental monitoring domains.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fe3O4 Magnetic Nanoparticles/ Graphene Oxide Nanosheets/Carbon Cloth as an Electrochemical Sensing Platform

In this work, for eliminating the (RR1346), considered to be a waste in wastewater from dye industries electrochemical advanced oxidation process has been used. Graphene oxide coated carbon cloth (GO/CC) and Fe3O4 /GO coated carbon cloth (Fe3O4/GO/CC) electrodes has been fabricated by synthesized GO and Fe3O4 nanoparticles. Characteristic properties such as surface morphology as the main reason...

متن کامل

ELECTROCHEMICAL BEHAVIOR OF GC, Pt AND Au ELECTRODES MODIFIED WITH THIN FILM OF COBALT HEXACYANOFERRATE

0A thin film of cobalt hexacyanoferrate (CoHCF), an analogue of mixed-valence Prussian blue, was deposited electrochemically on the glassy carbon, platinum and gold electrode surfaces in 0.5M KC1 solution. The electrochemical behavior of these modified electrodes show three couples of redox peaks by CV in a supporting electrolyte solution of 0.5M NaCl, whereas for Au modified electrode only ...

متن کامل

Laser-scribed graphene presents an opportunity to print a new generation of disposable electrochemical sensors.

Graphene application within electrochemical sensing has been widely reported, but mainly as a composite, which adds summative effects to an underlying electrode. In this work we report the use of laser-scribed graphene as a distinct electrode patterned on a non-conducting flexible substrate. The laser-scribed graphene electrode compared favourably to established carbon macroelectrodes when eval...

متن کامل

C4nr04221b 13613..13622 ++

Graphene application within electrochemical sensing has been widely reported, but mainly as a composite, which adds summative effects to an underlying electrode. In this work we report the use of laser-scribed graphene as a distinct electrode patterned on a non-conducting flexible substrate. The laser-scribed graphene electrode compared favourably to established carbon macroelectrodes when eval...

متن کامل

Electrochemical Sensing of H2S Gas in Air by Carboxylated Multi-walled Carbon Nanotubes

The electrochemical sensor for detecting hydrogen sulfide was fabricated. H2S gas molecules pass through polytetrafluoroethylene membrane with 0.22 mm pore size. Carboxylated multi-walled carbon nanotubes (MWCNTs-COOH) were used to fabricate working and counter electrodes. It can be seen from Field Emission Scanning Electron Microscopy (FESEM) images of the working electrode that...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 137 7  شماره 

صفحات  -

تاریخ انتشار 2012